Back to Search Start Over

An exploration of the effects of prefabricated and customized insoles on lower limb kinetics and kinematics during walking, stepping up and down tasks: A time series analysis

Authors :
Bianca Martins Lourenço
Fabricio Anicio Magalhães
Fernanda Muniz Vieira
Caroline Kokudai Reis
Henrique Silveira Costa
Vanessa Lara Araújo
Jim Richards
Renato Trede
Source :
Gait & Posture. 98:297-304
Publication Year :
2022
Publisher :
Elsevier BV, 2022.

Abstract

Prefabricated and customized insoles are used in clinical practice to reduce foot pronation. Although data exist on the effects at key points within the stance phase, exploring the impact of different insoles using time series analysis may reveal more detail about their efficacy.What are the effects revealed by a time series analysis of arch-supported prefabricated insoles (PREFABRICATED) versus arch-supported prefabricated insoles customized with a 6º medial wedge (CUSTOMIZED) on the lower limb biomechanics during walking, stepping up and down tasks in individuals with pronated feet?Nineteen individuals with excessive foot pronation performed walking, stepping up and down tasks using three insoles: CONTROL (flat insole), CUSTOMIZED, and PREFABRICATED. Angles and moments of ankle and knee coronal and hip transverse planes were compared between conditions using statistical parametric mapping (SPM).For walking, CUSTOMIZED reduced ankle eversion moment compared to CONTROL during midstance and PREFABRICATED during propulsion. CUSTOMIZED decreased KAM during midstance and propulsion compared to PREFABRICATED. Compared to CONTROL, CUSTOMIZED and PREFABRICATED reduced hip internal rotation during propulsion and loading response, respectively. CUSTOMIZED decreased eversion movement during midstance and propulsion for the stepping up task. PREFABRICATED reduced eversion movement during midstance in comparison to CONTROL. For the stepping down task, CUSTOMIZED increased eversion movement during propulsion compared to PREFABRICATED. CUSTOMIZED reduced hip internal rotation angle for stepping up task during propulsion, decreased medial rotation movement during midstance compared to CONTROL, and reduced medial rotation during midstance compared to PREFABRICATED. CUSTOMIZED increased KAM for stepping up and down tasks during propulsion.These findings suggest that both CUSTOMIZED and PREFABRICATED reduce foot pronation. However, non-local effects, such as changes in KAM and hip internal rotation, were seen only in the CUSTOMIZED. Therefore, CUSTOMIZED may be preferable if the objective is to modify the knee and hip mechanics.

Details

ISSN :
09666362
Volume :
98
Database :
OpenAIRE
Journal :
Gait & Posture
Accession number :
edsair.doi.dedup.....603cbce0fdcf75c547e4974f7632c270