Ethylene-vinyl alcohol copolymer (Onyx®) transarterial embolization for post-traumatic high-flow priapism

Authors :
Romaric Loffroy
Alain Foahom-Kamwa
Sylvain Favelier
Pierre Pottecher
Sophie Gehin
Olivier Chevallier
Laboratoire Electronique, Informatique et Image [UMR6306] (Le2i)
Université de Bourgogne (UB)-Centre National de la Recherche Scientifique (CNRS)-École Nationale Supérieure d'Arts et Métiers (ENSAM)
Arts et Métiers Sciences et Technologies
HESAM Université (HESAM)-HESAM Université (HESAM)-Arts et Métiers Sciences et Technologies
HESAM Université (HESAM)-HESAM Université (HESAM)-AgroSup Dijon - Institut National Supérieur des Sciences Agronomiques, de l'Alimentation et de l'Environnement
Department vascular, oncologic ans interventional radiology (CHU de Dijon)
Centre Hospitalier Universitaire de Dijon - Hôpital François Mitterrand (CHU Dijon)
Point médical (Dijon)
Laboratoire Electronique, Informatique et Image ( Le2i )
Université de Bourgogne ( UB ) -Centre National de la Recherche Scientifique ( CNRS ) -AgroSup Dijon - Institut National Supérieur des Sciences Agronomiques, de l'Alimentation et de l'Environnement
Centre Hospitalier Universitaire de Dijon - Hôpital François Mitterrand ( CHU Dijon )
Source :
Quantitative Imaging in Medicine and Surgery, Quantitative Imaging in Medicine and Surgery, AME Publishing, 2016, 6 (3), pp.323-327. ⟨10.21037/qims.2016.06.02⟩, Quantitative Imaging in Medicine and Surgery, AME Publishing, 2016, 6 (3), pp.323-327. 〈10.21037/qims.2016.06.02〉
Publication Year :
2016
Publisher :
AME Publishing Company, 2016.

Abstract

International audience; We report a case of high-flow priapism treated successfully with superselective embolization of the cavernous artery. A 16-year-old male developed post-traumatic priapism subsequent to a fall causing blunt perineal trauma. He presented to our hospital four days after trauma. Immediately after the injury, he suffered painless sustained incomplete erection. High-flow priapism was diagnosed on the basis of color doppler ultrasonography findings. Computed tomography scan showed a high-flow arterio-venous fistula with feeders from branches of the right internal iliac artery. Selective arteriography of the right internal pudendal artery demonstrated an arterio-cavernous fistula. The fistula was superselectively embolized with ethylene-vinyl alcohol copolymer (Onyx (R)) liquid agent and disappeared completely. Improvement was noted, with significant detumescence on table. This was later confirmed on repeat color Doppler imaging. At follow-up 3 months later, he had normal erectile function. To our knowledge, transarterial embolization of high-flow priapism with Onyx (R) has never been reported and appears to be a safe and effective treatment for managing patients with such a condition.