Back to Search Start Over

Influence of He and Ar Flow Rates and NaCl Concentration on the Size Distribution of Bubbles Generated by Power Ultrasound

Authors :
Judy Lee
Rachel Pflieger
Muthupandian Ashokkumar
Sergey I. Nikitenko
Sonochimie dans les Fluides Complexes (LSFC)
Institut de Chimie Séparative de Marcoule (ICSM - UMR 5257)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Ecole Nationale Supérieure de Chimie de Montpellier (ENSCM)-Institut de Chimie du CNRS (INC)-Université de Montpellier (UM)-Centre National de la Recherche Scientifique (CNRS)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Ecole Nationale Supérieure de Chimie de Montpellier (ENSCM)-Institut de Chimie du CNRS (INC)-Université de Montpellier (UM)-Centre National de la Recherche Scientifique (CNRS)
Center for Microbial Genetics and Genomics
Northern Arizona University [Flagstaff]
School of Chemistry [Melbourne]
Faculty of Science [Melbourne]
University of Melbourne-University of Melbourne
Centre National de la Recherche Scientifique (CNRS)-Institut de Chimie du CNRS (INC)-Université de Montpellier (UM)-Ecole Nationale Supérieure de Chimie de Montpellier (ENSCM)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Centre National de la Recherche Scientifique (CNRS)-Institut de Chimie du CNRS (INC)-Université de Montpellier (UM)-Ecole Nationale Supérieure de Chimie de Montpellier (ENSCM)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)
Source :
Journal of Physical Chemistry B, Journal of Physical Chemistry B, 2015, 119 (39), pp.12682-12688. ⟨10.1021/acs.jpcb.5b08723⟩, Journal of Physical Chemistry B, American Chemical Society, 2015, 119 (39), pp.12682-12688. ⟨10.1021/acs.jpcb.5b08723⟩
Publication Year :
2015

Abstract

A technique based on pulsed ultrasound and sonoluminescence emission was used to measure the size and size distribution of bubbles generated by 355 kHz power ultrasound under continuous Ar or He flow in aqueous NaCl solutions. It was observed that the bubble size strongly decreased with increasing NaCl concentration and that this decrease was much stronger than in solutions presaturated with Ar or He. This size decrease is attributed to the combination of the salting-out effect of the salt and the introduction of bubble nuclei by the continuous gas flow. Besides, the comparison of Ar and He bubbles underlines the effect of the gas diffusion coefficient on the bubble size reached.

Details

ISSN :
15205207 and 15206106
Volume :
119
Issue :
39
Database :
OpenAIRE
Journal :
The journal of physical chemistry. B
Accession number :
edsair.doi.dedup.....5f2f526f5202744d2e226ba432cfd777
Full Text :
https://doi.org/10.1021/acs.jpcb.5b08723⟩