Abstract
- Background Interference between pacemaker (PM) lead and tricuspid apparatus may cause tricuspid regurgitation (TR). However, data regarding TR in patients with implanted PM are controversial. Our aim is to find out the degree of TR in a group of patients before and following PM implantation in a prospective manner. Methods The study group consisted of the patients referred for implantation of permanent PM or implantable cardioverter defibrillator (ICD). All patients underwent two-dimensional and Doppler echocardiographic evaluation before and after device implantation. The severity of TR was qualitatively classified into four groups as normal or trivial, mild, moderate, or severe. All studies were reviewed for accuracy by a second independent interpreter. Results Sixty-one patients (mean age 53 +/- 8 years, 44 male) referred for PM (n = 55) or ICD (n = 6) implantation consisted of the study population. Echocardiographic degree of TR was mild in 21 (70%), moderate in 7 (23%) and severe in 2 (7%) patients before PM implantation. Following device implantation, mild TR was noted in 23 (76%), moderate in 10 (33%), and severe in 2 (6%) cases. After the procedure, the TR severity was increased from normal/trivial to mild in 5 (16%) cases and from mild to moderate in 3 (10%). There was no worsening of the severity of TR in patients with moderate regurgitation following device implantation. The severity of TR did not change at a mean follow-up of 6 +/- 3 months. Conclusions New or worsening TR is relatively rare after PM implantation. It is not associated with an acute worsening or clinical deterioration. But echocardiographic follow-up is recommended to monitor other complications in chronic phase.
- Subjects :
- Cardiomyopathy, Dilated
Male
Pulmonary and Respiratory Medicine
Pacemaker, Artificial
medicine.medical_specialty
Time Factors
medicine.medical_treatment
Cardiomyopathy
Coronary Artery Disease
Regurgitation (circulation)
Severity of Illness Index
Internal medicine
Severity of illness
medicine
Humans
Prospective Studies
Lead (electronics)
Prospective cohort study
business.industry
Middle Aged
Tricuspid insufficiency
medicine.disease
Implantable cardioverter-defibrillator
Echocardiography, Doppler
Tricuspid Valve Insufficiency
Defibrillators, Implantable
Surgery
Treatment Outcome
Cardiology
Population study
Female
Cardiology and Cardiovascular Medicine
business
Follow-Up Studies
Subjects
Details
- ISSN :
- 15408191 and 08860440
- Volume :
- 21
- Database :
- OpenAIRE
- Journal :
- Journal of Cardiac Surgery
- Accession number :
- edsair.doi.dedup.....5d2f1b444e07cf88c2eb3821e3606825
- Full Text :
- https://doi.org/10.1111/j.1540-8191.2006.00251.x