Back to Search Start Over

Data from First-in-Human Assessment of cRGD-ZW800-1, a Zwitterionic, Integrin-Targeted, Near-Infrared Fluorescent Peptide in Colon Carcinoma

Authors :
Alexander L. Vahrmeijer
Jacobus Burggraaf
John V. Frangioni
J. Sven D. Mieog
Denise E. Hilling
Fabian A. Holman
Koen C.M.J. Peeters
Jaap Vuijk
Taryn L. March
A. Rob P.M. Valentijn
Anton G.T. Terwisscha van Scheltinga
Michiel J. van Esdonk
Okker D. Bijlstra
Shadhvi S. Bhairosingh
Henricus J.M. Handgraaf
Marion M. Deken
Kim S. de Valk
Publication Year :
2023
Publisher :
American Association for Cancer Research (AACR), 2023.

Abstract

Purpose:Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery.Experimental Design:We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer.Results:cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio.Conclusions:cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.

Details

Database :
OpenAIRE
Accession number :
edsair.doi.dedup.....5d0680f6b7e0dc10cb1808c40fcf076e
Full Text :
https://doi.org/10.1158/1078-0432.c.6529526.v1