Back to Search Start Over

Impact of subcutaneous tunnels on peripherally inserted catheter placement: a multicenter retrospective study

Authors :
Il Jung Kim
Jae Hwan Lee
Soon Gu Cho
Jong Hyun Byeon
Eung Tae Kim
Dong Jae Shim
Hun Jae Lee
Source :
European Radiology. 29:2716-2723
Publication Year :
2018
Publisher :
Springer Science and Business Media LLC, 2018.

Abstract

To evaluate the impact of subcutaneous tunneling on peripherally inserted central catheter (PICC) placement in terms of central line–associated bloodstream infections (CLABSIs). Our dual-facility central institutional review board approved this retrospective study. We compared 302 of 327 consecutive recipients (mean age [± SD], 68.0 ± 15.9 years; men, 134; women, 168) of tunneled PICCs (October 2017 to May 2018) with 309 of 328 consecutive recipients (mean age, 68.7 ± 14.6 years; men, 142; women, 167) of conventional PICCs (April 2016 to September 2017). Tunnels were made near puncture sites (~ 1 in. away) using hemostats or puncture needles. In each group, procedure times and rates of complications, including CLABSI, entry-site infection, dislocation, thrombophlebitis, and occlusion, were examined. Risk factors for CLABSI were analyzed via logistic and Cox regression models. Subcutaneous tunnels were achieved in all patients, enabling successful peripheral vein cannulations. Group procedure times were similar (p = 0.414). CLABSI proved to be significantly less frequent after tunneling (8/6972 catheter-days) than after conventional (28/7574 catheter-days) PICC placement (adjusted hazard ratio = 0.328; 95% confidence interval, 0.149–0.721). Other risk factors (i.e., age, gender, comorbidity, PICC duration, veins, hospital stay, and intensive care unit stay) showed no significant correlations with CLABSI. Compared with conventional means, a subcutaneous tunneling approach for PICC placement significantly reduces the rate of CLABSI. • Subcutaneous tunnels created to place peripherally inserted central catheters significantly reduced catheter-associated bloodstream infections. • Subcutaneous tunnel creation did not significantly prolong procedural time. • There were no subcutaneous tunnel-related complications.

Details

ISSN :
14321084 and 09387994
Volume :
29
Database :
OpenAIRE
Journal :
European Radiology
Accession number :
edsair.doi.dedup.....5c9574720795d76c4da24411147ef11a
Full Text :
https://doi.org/10.1007/s00330-018-5917-x