- Source :
- BMC Medical Imaging, BMC Medical Imaging, Vol 20, Iss 1, Pp 1-10 (2020)
- Publication Year :
- 2020
- Publisher :
- BioMed Central, 2020.
-
Abstract
- Background Ultra-high field magnetic resonance imaging (MR) may be used to improve intracranial blood flow measurements. However, standard cardiac synchronization methods tend to fail at ultra-high field MR. Therefore, this study aims to investigate an alternative synchronization technique using Doppler ultrasound. Methods Healthy subjects (n = 9) were examined with 7T MR. Flow was measured in the M1-branch of the middle cerebral artery (MCA) and in the cerebral aqueduct (CA) using through-plane phase contrast (2D flow). Flow in the circle of Willis was measured with three-dimensional, three-directional phase contrast (4D flow). Scans were gated with Doppler ultrasound (DUS) and electrocardiogram (ECG), and pulse oximetry data (POX) was collected simultaneously. False negative and false positive trigger events were counted for ECG, DUS and POX, and quantitative flow measures were compared. Results There were fewer false positive triggers for DUS compared to ECG (5.3 ± 11 vs. 25 ± 31, p = 0.031), while no other measured parameters differed significantly. Net blood flow in M1 was similar between DUS and ECG for 2D flow (1.5 ± 0.39 vs. 1.6 ± 0.41, bias ± 1.96SD: − 0.021 ± 0.36) and 4D flow (1.8 ± 0.48 vs. 9 ± 0.59, bias ± 1.96SD: − 0.086 ± 0.57 ml). Net CSF flow per heart beat in the CA was also similar for DUS and ECG (3.6 ± 2.1 vs. 3.0 ± 5.8, bias ± 1.96SD: 0.61 ± 13.6 μl). Conclusion Gating with DUS produced fewer false trigger events than using ECG, with similar quantitative flow values. DUS gating is a promising technique for cardiac synchronization at 7T.
- Subjects :
- Neurovascular
Adult
Male
medicine.medical_specialty
lcsh:Medical technology
Ultra-high field MRI
Cardiac-Gated Imaging Techniques
Gating
Doppler ultrasound
030218 nuclear medicine & medical imaging
03 medical and health sciences
Electrocardiography
Young Adult
0302 clinical medicine
Reference Values
medicine.artery
Internal medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Flow quantification
False Positive Reactions
Oximetry
False Negative Reactions
Cardiac synchronization
medicine.diagnostic_test
business.industry
ECG
Magnetic resonance imaging
Ultrasonography, Doppler
Blood flow
Cerebral Arteries
Middle Aged
Pulse oximetry
Flow (mathematics)
lcsh:R855-855.5
Technical Advance
Cerebral aqueduct
Middle cerebral artery
Cardiology
Female
business
030217 neurology & neurosurgery
Blood Flow Velocity
Circle of Willis
Subjects
Details
- Language :
- English
- ISSN :
- 14712342
- Volume :
- 20
- Database :
- OpenAIRE
- Journal :
- BMC Medical Imaging
- Accession number :
- edsair.doi.dedup.....5b583fdc2e566ff988a7bb100cddb178