Use of a pH-sensitive fluorescent probe for measuring intracellular pH of Caco-2 cells

Authors :
Steven M. Dinh
Earvin Liang
Puchun Liu
Source :
International journal of pharmaceutics. 338(1-2)
Publication Year :
2006

Abstract

This paper describes the application of a pH-sensitive fluorescent probe [2',7'-bis(2-carboxylethyl)-5(6)-carboxyfluorescein or BCECF] to measure intracellular pH (pH(i)) changes in Caco-2 cells. As a function of BCECF's ionization, the fluorescence was monitored at lambda(ex)=440 and 503nm, and lambda(em)=535nm. Time course studies were conducted with the addition of two weak acid delivery agents, one weak base delivery agent, oleic acid, or tetradecylamine. When applicable, 10microM bovine serum albumin or 10mM ammonium chloride was added into the cell suspension to hinder the pH gradient effect. Adding a weak acid at 2, 10, or 50mM to the cell suspension, the pH(i) dropped substantially from 7.4 to 7.1, 6.9, or 6.7, respectively. The pH(i) then increased gradually over a 10-min period but did not return to its initial value. Conversely, the pH(i) increased instantaneously after the addition of a weak base. When Caco-2 cells were placed in solutions with different bulk pH (7.0, 7.5, and 8.0), the lower the pH in which the cells were exposed, the larger the pH(i) drop occurred with the addition of an acid. The results suggest that these weak acids or bases are transported transcellularly across Caco-2 cells.