Back to Search Start Over

Short rotator tendons do not increase intracapsular pressure in severe osteoarthritic hips

Authors :
Otto Robertsson
Alfredas Smailys
Hans Wingstrand
Arunas Gelmanas
Sarunas Tarasevicius
Source :
BMC Musculoskeletal Disorders, Vol 10, Iss 1, p 12 (2009), BMC Musculoskeletal Disorders
Publication Year :
2009
Publisher :
BMC, 2009.

Abstract

Background While a relation between pain and intracapsular pressure in the hip joint has previously been reported by some of the present authors, a newly published study including patients with severe osteoarthritis was not able to confirm this finding. This stimulated us to investigate the role of short rotators in relation to intracapsular pressure and pain in osteoarthritic hips. Methods We measured the intracapsular hydrostatic pressure peroperatively in 25 total hip arthroplasty patients with severe osteoarthritis in various positions of the hip joint before and after short rotator release, and correlated these pressures to pain. Results Release of the short rotators did not change the intracapsular pressure in any position except in 45° flexion, in which the pressure increased (p = 0.002). We found no correlation between intracapsular pressure and pain before or after short rotator release. Conclusion We could not show that the rotators directly affected the pressure nor could we find a relation between pressure and pain.

Details

Language :
English
ISSN :
14712474
Volume :
10
Issue :
1
Database :
OpenAIRE
Journal :
BMC Musculoskeletal Disorders
Accession number :