Back to Search
Start Over
Single-center experience demonstrating low adverse events and high efficacy with self-expandable metal esophageal and biliary stents for pseudocyst and walled off necrosis drainage
- Source :
- Endoscopy International Open, Endoscopy International Open, Vol 08, Iss 09, Pp E1156-E1160 (2020)
- Publication Year :
- 2020
- Publisher :
- Georg Thieme Verlag KG, 2020.
-
Abstract
- Background and study aims Lumen-apposing metal stents (LAMS) have been designed as proprietary stents for the management of pseudocysts (PC)/walled off necrosis (WON). There has been concern about adverse events (AEs) with LAMS including bleeding, buried stent syndrome and migration. Prior to LAMS becoming available, fully-covered self-expandable metal esophageal and biliary stents (FCSEMSs) were used off-label for management of PC/WON with many centers demonstrating low rates of AEs. The primary aim of this study was to study the safety and efficacy of FCSEMS for the management of pseudocysts/WON. Patients and methods This was a retrospective review of all endoscopic ultrasound (EUS)-guided placement of FCSEMSs for drainage of PC/WON cases performed at our institution over 4-year period. The primary outcomes studied were technical success, AEs, PC/WON resolution, and salvage surgical/radiologic intervention. Results Technical success achieved in 65 of 65 (100 %) study patients. An AE occurred 0 of 25 patients (0 %) with PC, and in 10 of 40 patients (25 %) with WON: bleeding (3 %), migration (5 %) and stent dysfunction/infection (18 %). There was resolution in 25 of 25 patients (100 %) with a PC and 31 of 40 patients (78 %) with a WON. Salvage therapy by interventional radiology or surgery was performed in nine of 40 patients (22 %). Conclusions This single-center 4-year experience in the pre-LAMS era showed that FCSEMS was safe and effective in all patients with PC and over 75 % of patients with WON. Given the large cost differential between LAMS and FCSEMS and the efficacy and safety shown with FCSEMS, we believe that FCSEMS should still be considered a first-line option for patients with pancreatic fluid collections, particularly in patients with PCs.
- Subjects :
- Endoscopic ultrasound
Original article
medicine.medical_specialty
medicine.diagnostic_test
business.industry
medicine.medical_treatment
Salvage therapy
Stent
Interventional radiology
Single Center
Surgery
03 medical and health sciences
0302 clinical medicine
030220 oncology & carcinogenesis
Walled off necrosis
Medicine
Biliary stent
lcsh:Diseases of the digestive system. Gastroenterology
030211 gastroenterology & hepatology
Pharmacology (medical)
lcsh:RC799-869
business
Adverse effect
Subjects
Details
- ISSN :
- 21969736 and 23643722
- Database :
- OpenAIRE
- Journal :
- Endoscopy International Open
- Accession number :
- edsair.doi.dedup.....5a776abff0803c4bcfb6be565a98ad5c