Comparison of video-based methods for respiration rhythm measurement

Authors :
M A García-González
Juan Ramos-Castro
V. Ferrer-Mileo
Federico Guede-Fernandez
M. Fernandez-Chimeno
Marc Mateu-Mateus
Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
Universitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica
Source :
Recercat. Dipósit de la Recerca de Catalunya, instname, UPCommons. Portal del coneixement obert de la UPC, Universitat Politècnica de Catalunya (UPC)
Publication Year :
2019
Publisher :
Elsevier BV, 2019.

Abstract

The aim of this work is to characterize the di erences in the respiratory rhythm obtained through three video based methods by comparing the obtained respiratory signals with the one obtained with the gold standard method in adult population. The analysed methods are an RGB camera, a depth camera and a thermal camera while the gold standard is an inductive thorax plethysmography system (Respiband system from BioSignals Plux). 21 healthy subjects where measured, performing 4 tests for each subject. The respiratory rhythm and its variability was obtained from the four respiratory signals (3 video methods and gold standard). The signal acquisition was performed with custom and proprietary algorithms. To characterize the respiratory rhythm and its variability obtained with the di erent video sources and gold standard, the instantaneous frequency, Bland-Altman plots and standard deviation of the error between video methods and the gold standard have been computed. The depth and RGB camera present high agreement with no statistical di erences between them, with errors when comparing with the gold standard in the range of mHz. The thermal camera performs poorly if compared with the two other methods, nevertheless it cannot be discarded directly because some errors produced by the subjects head movement could not be corrected. From these results we conclude that the depth and RGB camera, and their respective acquisition algorithms) can be used in controlled conditions to measure respiration rhythm and its variability. The thermal camera on the other hand, although it can not be discarded directly, performed poorly if compared with the other two methods. Further studies are needed to con rm that these methods can be used in real life conditions.

Details

ISSN :
17468094
Volume :
51
Database :
OpenAIRE
Journal :
Biomedical Signal Processing and Control
Accession number :
edsair.doi.dedup.....58cfad42008ef0600363fd7d91d47c1e
Full Text :
https://doi.org/10.1016/j.bspc.2019.02.004