Back to Search
Start Over
Validation of an analytical method for a potent antitumor agent, TZT-1027, in plasma using liquid chromatography–mass spectrometry
- Source :
- Journal of Chromatography B: Biomedical Sciences and Applications. 762:155-163
- Publication Year :
- 2001
- Publisher :
- Elsevier BV, 2001.
-
Abstract
- A sensitive and specific analytical method for a potent antitumor agent, TZT-1027, in plasma has been developed using liquid chromatography–mass spectrometry (LC–MS) with [2H4]TZT-1027 as an internal standard (I.S.). A plasma sample was purified by solid-phase extraction on a C18 cartridge, followed by solvent extraction with diethyl ether. The extract was then injected into the LC–MS system. Chromatography was carried out on a C18 reversed-phase column using acetonitrile–0.05% trifluoroacetic acid (TFA) (55:45) as a mobile phase. Mass spectrometric analysis was performed in atmospheric pressure chemical ionization (APCI) mode with positive ion detection, and the protonated molecular ions ([M+H]+) of TZT-1027 and I.S. were monitored to allow quantitation. The method was applied to the determination of TZT-1027 in human, monkey, dog, rat and mouse plasma. As far as the sample preparation was concerned, good recoveries (73.5–99.1%) were obtained. The calibration curves were linear over the range of 0.25–100 ng per 1 ml of human, dog and rat plasma, per 0.5 ml of monkey plasma, and per 0.1 ml of mouse plasma. From the intra- and inter-day accuracy and precision, the present method satisfies the accepted criteria for bioanalytical method validation. TZT-1027 was stable when stored below −15°C for 6 months in human plasma and for 3 weeks in plasma from other species. TZT-1027 was also stable in plasma through at least three freeze–thaw cycles.
- Subjects :
- Bioanalysis
Chromatography
Chemistry
Reproducibility of Results
Antineoplastic Agents
Atmospheric-pressure chemical ionization
General Chemistry
Mass spectrometry
Sensitivity and Specificity
Mass Spectrometry
chemistry.chemical_compound
Liquid chromatography–mass spectrometry
Calibration
Trifluoroacetic acid
Animals
Humans
Sample preparation
Diethyl ether
Oligopeptides
Quantitative analysis (chemistry)
Chromatography, Liquid
Subjects
Details
- ISSN :
- 03784347
- Volume :
- 762
- Database :
- OpenAIRE
- Journal :
- Journal of Chromatography B: Biomedical Sciences and Applications
- Accession number :
- edsair.doi.dedup.....589b42c551576c14281b518f754d9355
- Full Text :
- https://doi.org/10.1016/s0378-4347(01)00360-7