Snare-assisted anterograde balloon mitral and aortic valvotomy using Inoue balloon catheter

Authors :
C.C. Velayudhan
M.N. Krishnan
Francis Johnson
D. Vinaykumar
K. Venugopal
C.G. Sajeev
M.D. Syamkumar
T.G. Jayakumar
Source :
International Journal of Cardiology. 114:E9-E11
Publication Year :
2007
Publisher :
Elsevier BV, 2007.

Abstract

We performed concurrent antegrade mitral and aortic valvotomy using Inoue dilatation catheter in 3 cases of combined rheumatic mitral and aortic stenosis. Following mitral valvotomy by standard procedure, aortic valve was crossed with the help of a floatation catheter. Stiff long length guide wire was fixed in descending aorta using a snare. Inoue catheter was threaded over the wire across the aortic valve and aortic valvotomy completed. Mitral valve area increased from mean 1 cm2 to 2 cm2; aortic gradient dropped from mean of 97 mm to 36 mm. Concurrent anterograde balloon mitral and aortic valvotomy may be effective and safe.