Back to Search
Start Over
Adaptive optics microspectrometer for cross-correlation measurement of microfluidic flows
- Source :
- Journal of Biomedical Optics
- Publication Year :
- 2019
- Publisher :
- Society of Photo-Optical Instrumentation Engineers, 2019.
-
Abstract
- Mapping flows in vivo is essential for the investigation of cardiovascular pathologies in animal models. The limitation of optical-based methods, such as space-time cross correlation, is the scattering of light by the connective and fat components and the direct wave front distortion by large inhomogeneities in the tissue. Nonlinear excitation of the sample fluorescence helps us by reducing light scattering in excitation. However, there is still a limitation on the signal-background due to the wave front distortion. We develop a diffractive optical microscope based on a single spatial light modulator (SLM) with no movable parts. We combine the correction of wave front distortions to the cross-correlation analysis of the flow dynamics. We use the SLM to shine arbitrary patterns of spots on the sample, to correct their optical aberrations, to shift the aberration corrected spot array on the sample for the collection of fluorescence images, and to measure flow velocities from the cross-correlation functions computed between couples of spots. The setup and the algorithms are tested on various microfluidic devices. By applying the adaptive optics correction algorithm, it is possible to increase up to 5 times the signal-to-background ratio and to reduce approximately of the same ratio the uncertainty of the flow speed measurement. By working on grids of spots, we can correct different aberrations in different portions of the field of view, a feature that allows for anisoplanatic aberrations correction. Finally, being more efficient in the excitation, we increase the accuracy of the speed measurement by employing a larger number of spots in the grid despite the fact that the two-photon excitation efficiency scales as the fourth power of this number: we achieve a twofold decrease of the uncertainty and a threefold increase of the accuracy in the evaluation of the flow speed.
- Subjects :
- Paper
Optics and Photonics
Light
Microfluidics
Biomedical Engineering
microfluidic
Field of view
01 natural sciences
Light scattering
adaptive optics
010309 optics
Biomaterials
Optics
Distortion
Lab-On-A-Chip Devices
0103 physical sciences
Image Processing, Computer-Assisted
Animals
Scattering, Radiation
Colloids
Adaptive optics
General
Lenses
Physics
Wavefront
adaptive optic
Microscopy
Photons
Spatial light modulator
Cross-correlation
business.industry
Reproducibility of Results
flow mapping
Equipment Design
Atomic and Molecular Physics, and Optics
Electronic, Optical and Magnetic Materials
Rats
cross-correlation spectroscopy
adattive optics, cross-correlation, microfluidics
Cardiovascular Diseases
Spectrophotometry
Calibration
business
Excitation
Algorithms
Software
Subjects
Details
- Language :
- English
- ISSN :
- 15602281 and 10833668
- Volume :
- 24
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Journal of Biomedical Optics
- Accession number :
- edsair.doi.dedup.....57107c47c068bae0fdadb0d0966e40e9