Back to Search
Start Over
An in vitro evaluation of the pressure generated during programmed intermittent epidural bolus injection at varying infusion delivery speeds
- Source :
- Journal of Clinical Anesthesia. 34:632-637
- Publication Year :
- 2016
- Publisher :
- Elsevier BV, 2016.
-
Abstract
- Programmed intermittent bolus injection of epidural anesthetic solution results in decreased anesthetic consumption and better patient satisfaction compared with continuous infusion, presumably by better spread of the anesthetic solution in the epidural space. It is not known whether the delivery speed of the bolus injection influences analgesia outcomes. The objective of this in vitro study was to determine the pressure generated by a programmed intermittent bolus pump at 4 infusion delivery speeds through open-ended, single-orifice and closed-end, multiorifice epidural catheters.In vitro observational study.Not applicable.Not applicable.A CADD-Solis Pain Management System v3.0 with Programmed Intermittent Bolus Model 2110 was connected via a 3-way adapter to an epidural catheter and a digital pressure transducer. Pressures generated by delivery speeds of 100, 175, 300, and 400 mL/h of saline solution were tested with 4 epidural catheters (2 single orifice and 2 multiorifice). These runs were replicated on 5 pumps. Analysis of variance was used to compare the mean peak pressures of each delivery speed within each catheter group (single orifice and multiorifice).Thirty runs at each delivery speed were performed with each type of catheter for a total of 240 experimental runs. Peak pressure increased with increasing delivery speeds in both catheter groups (P.001). Peak pressures were higher with the multiorifice catheter compared with the single-orifice catheter at all delivery speeds (P.001, for all).Using a pump designed for programmed intermittent infusion boluses, the delivery speed of saline solution through epidural catheters was directly related to the peak pressures. Future work should evaluate whether differences in the delivery speed of anesthetic solution into the epidural space correlate with differences in the duration and quality of analgesia during programmed intermittent epidural bolus delivery.
- Subjects :
- Anesthesia, Epidural
Catheters
medicine.medical_treatment
Injections, Epidural
03 medical and health sciences
0302 clinical medicine
Bolus (medicine)
030202 anesthesiology
Pressure
medicine
Humans
Pain Management
Anesthetics, Local
Saline
Infusion Pumps
Bolus injection
business.industry
Pain management
Epidural space
Analgesia, Epidural
Catheter
Anesthesiology and Pain Medicine
medicine.anatomical_structure
Patient Satisfaction
Anesthesia
Anesthetic
Analgesia, Obstetrical
Female
business
030217 neurology & neurosurgery
Body orifice
medicine.drug
Subjects
Details
- ISSN :
- 09528180
- Volume :
- 34
- Database :
- OpenAIRE
- Journal :
- Journal of Clinical Anesthesia
- Accession number :
- edsair.doi.dedup.....55c906f4c4ded85d7a004f8ba526a432
- Full Text :
- https://doi.org/10.1016/j.jclinane.2016.06.017