A validated UHPLC-MS/MS method for rapid determination of senicapoc in plasma samples
- Source :
- Journal of Pharmaceutical and Biomedical Analysis, Sørensen, L K, Petersen, A, Granfeldt, A, Simonsen, U & Hasselstrøm, J B 2021, ' A validated UHPLC-MS/MS method for rapid determination of senicapoc in plasma samples. ', Journal of Pharmaceutical and Biomedical Analysis, vol. 197, 113956 . https://doi.org/10.1016/j.jpba.2021.113956
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- The clinically tested KCa3.1 channel blocker, senicapoc, has been proven to have excellent pharmacological properties and prior clinical trials found it to be safe for use in patients with sickle cell anaemia. Currently, several preclinical projects are aiming to repurpose senicapoc for other indications, but well-described analytical methods in the literature are lacking. Our aim was to develop a sensitive, rapid and accurate ultra-high-performance liquid chromatography-tandem mass spectrometry method using pneumatically assisted electrospray ionisation (UHPLC-ESI-MS/MS) suitable for the determination of senicapoc in plasma samples. Unfortunately, direct analysis of senicapoc in crude acetonitrile extracts of human plasma samples by UHPLC-ESI-MS/MS was subjected to significant and variable ion suppression from coeluting phospholipids (PLs). The interferences were mainly caused by the presence of phosphatidylcholine and phosphatidylethanolamine classes of PLs, including their lyso-products. However, the PLs were easily removed from crude extracts by filtration through a sorbent with Lewis acid properties which decreased the total ion suppression effect to approximately 5%. Based on this technique, a simple high-throughput UHPLC-MS/MS method was developed and validated for the determination of senicapoc in 100-μL plasma samples. The lower limit of quantification was 0.1 ng/mL. The mean true extraction recovery was close to 100 %. The relative intra-laboratory reproducibility standard deviations of the measured concentrations were 8% and 4% at concentrations of 0.1 ng/mL and 250 ng/mL, respectively. The trueness expressed as the relative bias of the test results was within ± 2% at concentrations of 1 ng/mL or higher.
- Subjects :
- Spectrometry, Mass, Electrospray Ionization
Electrospray
Swine
Senicapoc
Clinical Biochemistry
Pharmaceutical Science
Ion suppression in liquid chromatography–mass spectrometry
Spectrometry, Mass, Electrospray Ionization/methods
Mass spectrometry
Tandem Mass Spectrometry/methods
01 natural sciences
Article
Analytical Chemistry
Plasma
chemistry.chemical_compound
Trityl Compounds/blood
Tandem Mass Spectrometry
Limit of Detection
Phosphatidylcholine
Acetamides
Drug Discovery
Humans
Animals
Channel blocker
Phospholipids/blood
Filtration/methods
Chromatography, High Pressure Liquid
Phospholipids
plasma
Spectroscopy
Detection limit
Reproducibility
Chromatography
010405 organic chemistry
Chemistry
010401 analytical chemistry
Extraction (chemistry)
COVID-19
Reproducibility of Results
Acetamides/blood
Trityl Compounds
Plasma/chemistry
0104 chemical sciences
UHPLC-MS/MS
Female
Chromatography, High Pressure Liquid/methods
Filtration
Subjects
Details
- ISSN :
- 07317085
- Volume :
- 197
- Database :
- OpenAIRE
- Journal :
- Journal of Pharmaceutical and Biomedical Analysis
- Accession number :
- edsair.doi.dedup.....5561a7687963794c59323e0c7ae805ce
- Full Text :
- https://doi.org/10.1016/j.jpba.2021.113956