Back to Search Start Over

Real-time intraoperative detection of breast cancer using near-infrared fluorescence imaging and Methylene Blue

Authors :
Boudewijn E. Schaafsma
J.R. van der Vorst
John V. Frangioni
G.J. Liefers
Martin C. Boonstra
C.J.H. van de Velde
Alexander L. Vahrmeijer
Floris P. R. Verbeek
Quirijn R.J.G. Tummers
Source :
EJSO-European Journal of Surgical Oncology, 40(7), 850-858
Publication Year :
2014

Abstract

Background Despite recent developments in preoperative breast cancer imaging, intraoperative localization of tumor tissue can be challenging, resulting in tumor-positive resection margins during breast conserving surgery. Based on certain physicochemical similarities between Technetium( 99m Tc)-sestamibi (MIBI), an SPECT radiodiagnostic with a sensitivity of 83–90% to detect breast cancer preoperatively, and the near-infrared (NIR) fluorophore Methylene Blue (MB), we hypothesized that MB might detect breast cancer intraoperatively using NIR fluorescence imaging. Methods Twenty-four patients with breast cancer, planned for surgical resection, were included. Patients were divided in 2 administration groups, which differed with respect to the timing of MB administration. N = 12 patients per group were administered 1.0 mg/kg MB intravenously either immediately or 3 h before surgery. The mini-FLARE imaging system was used to identify the NIR fluorescent signal during surgery and on post-resected specimens transferred to the pathology department. Results were confirmed by NIR fluorescence microscopy. Results 20/24 (83%) of breast tumors (carcinoma in N = 21 and ductal carcinoma in situ in N = 3) were identified in the resected specimen using NIR fluorescence imaging. Patients with non-detectable tumors were significantly older. No significant relation to receptor status or tumor grade was seen. Overall tumor-to-background ratio (TBR) was 2.4 ± 0.8. There was no significant difference between TBR and background signal between administration groups. In 2/4 patients with positive resection margins, breast cancer tissue identified in the wound bed during surgery would have changed surgical management. Histology confirmed the concordance of fluorescence signal and tumor tissue. Conclusions This feasibility study demonstrated an overall breast cancer identification rate using MB of 83%, with real-time intraoperative guidance having the potential to alter patient management.

Details

Language :
English
Database :
OpenAIRE
Journal :
EJSO-European Journal of Surgical Oncology, 40(7), 850-858
Accession number :
edsair.doi.dedup.....551b0d9bfdc0aca42cc5338454190289