Towards a liquid Argon TPC without evacuation: filling of a 6 m3vessel with argon gas from air to ppm impurities concentration through flushing

Authors :
L. Knecht
K. Mavrokoridis
C. Touramanis
André Rubbia
A. Gendotti
A. Marchionni
F. Resnati
K. J. McCormick
A. Curioni
J. P. Coleman
M Lewis
L. Epprecht
G. Natterer
D. Lussi
Source :
J.Phys.Conf.Ser.
Publication Year :
2011
Publisher :
IOP Publishing, 2011.

Abstract

In this paper we present a successful experimental test of filling a volume of 6 m$^3$ with argon gas, starting from normal ambient air and reducing the impurities content down to few parts per million (ppm) oxygen equivalent. This level of contamination was directly monitored measuring the slow component of the scintillation light of the Ar gas, which is sensitive to {\it all} sources of impurities affecting directly the argon scintillation.<br />Comment: 9 pages, 6 figures, to appear in Proc. 1st International Workshop towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba, March 2010