Back to Search
Start Over
A practical algorithm to reduce false critical ECG alarms using arterial blood pressure and/or photoplethysmogram waveforms
- Source :
- Physiological Measurement. 37:1355-1369
- Publication Year :
- 2016
- Publisher :
- IOP Publishing, 2016.
-
Abstract
- There has been a high rate of false alarms for the critical electrocardiogram (ECG) arrhythmia events in intensive care units (ICUs), from which the 'crying-wolf' syndrome may be resulted and patient safety may be jeopardized. This article presents an algorithm to reduce false critical arrhythmia alarms using arterial blood pressure (ABP) and/or photoplethysmogram (PPG) waveform features. We established long duration reference alarm datasets which consist of 573 ICU waveform-alarm records (283 for development set and 290 for test set) with total length of 551 patent days. Each record has continuous recordings of ECGs, ABP and/or PPG signals and contains one or multiple critical ECG alarms. The average length of a record is 23 h. There are totally 2408 critical ECG alarms (1414 in the development set and 994 in the test set), each of which was manually annotated by experts. The algorithm extracts ABP/PPG pulse features on a beat-by-beat basis. For each pulse, five event feature indicators (EFIs), which correspond to the five critical ECG alarms, are generated. At the time of a critical ECG alarm, the corresponding EFI values of those ABP/PPG pulses around the alarm time are checked for adjudicating (accept/reject) this alarm. The algorithm retains all (100%) the true alarms and significantly reduces the false alarms. Our results suggest that the algorithm is effective and practical on account of its real-time dynamic processing mechanism and computational efficiency.
- Subjects :
- Physiology
Computer science
Speech recognition
Biomedical Engineering
Biophysics
Blood Pressure
030204 cardiovascular system & hematology
Electrocardiography
03 medical and health sciences
ALARM
0302 clinical medicine
Physiology (medical)
Photoplethysmogram
Intensive care
medicine
Humans
Waveform
False Positive Reactions
Photoplethysmography
Monitoring, Physiologic
Signal processing
medicine.diagnostic_test
Arrhythmias, Cardiac
Signal Processing, Computer-Assisted
030208 emergency & critical care medicine
Intensive Care Units
Feature (computer vision)
Clinical Alarms
Test set
Algorithms
Subjects
Details
- ISSN :
- 13616579 and 09673334
- Volume :
- 37
- Database :
- OpenAIRE
- Journal :
- Physiological Measurement
- Accession number :
- edsair.doi.dedup.....54006d9a8b1ef560031bf19473cbf55e
- Full Text :
- https://doi.org/10.1088/0967-3334/37/8/1355