Back to Search Start Over

A new methodological approach: The combined use of two-stage streaker samplers and optical particle counters for the characterization of airborne particulate matter

Authors :
Mazzei, F.
D'Alessandro, Alessandra
Lucarelli, F.
Nava, S.
Prati, Paolo
Valli, G.
Vecchi, R.
Source :
Atmospheric Environment. 41:5525-5535
Publication Year :
2007
Publisher :
Elsevier BV, 2007.

Abstract

We describe a new experimental methodology based on the contemporary use of two-stage continuous streaker samplers and optical particle counters. This is a complementary approach to size-segregated particulate matter (PM) sampling, and it is able to give information on the elemental size distribution and to assess the contribution of major PM source to size bins. PM samples in the fine and coarse fraction of PM10 have been collected by a two-stage streaker sampler and analyzed by particle-induced X-ray emission (PIXE) to obtain elemental concentration time series with hourly resolution. PM sources and profiles were singled out by positive matrix factorization (PMF). A multi-linear regression of size-segregated number of particles versus the sources, resolved by PMF, made possible the apportionment of size-segregated particles number in a fast and direct way. Results obtained in three sampling sites, located in different urban districts are discussed.

Details

ISSN :
13522310
Volume :
41
Database :
OpenAIRE
Journal :
Atmospheric Environment
Accession number :
edsair.doi.dedup.....52cf67f789a44c009629ed11f52c00b2