Back to Search Start Over

Distribution and Classification of Peripapillary Retinal Nerve Fiber Layer Thickness in Healthy Young Adults

Authors :
Antony Clark
Fred K. Chen
David A. Mackey
Samantha Sze Yee Lee
Gareth Lingham
Seyhan Yazar
Jason Charng
Source :
Translational Vision Science & Technology
Publication Year :
2021
Publisher :
Association for Research in Vision and Ophthalmology (ARVO), 2021.

Abstract

Purpose: To report the distribution of peripapillary retinal nerve fiber layer (RNFL) thickness in healthy young adults, investigate factors associated with RNFL thickness, and report the percentage of outside normal limits (ONL) and borderline (BL) RNFL thickness classifications based on the optical coherence tomography (OCT) manufacturer reference database. Methods: Participants of the Raine Study Generation 2 cohort (aged 18–22 years) underwent spectral domain OCT imaging with an RNFL circle scan. Eyes with inadequate scans or optic nerve pathology were excluded. Linear mixed models were used to analyze associations. Results: Data were available for 1288 participants (mean age, 20.0 years). Mean RNFL thicknesses in right and left eyes, respectively, were global = 100.5 µm, 100.3 µm (P = 0.03); temporal = 73.1 µm, 68.9 µm (P < 0.001); superotemporal = 140.6 µm, 136.3 µm (P < 0.001); superonasal = 104.9 µm, 115.1 µm (P < 0.001); nasal = 79.7 µm, 79.1 µm (P = 0.09); inferonasal = 109.8 µm, 111.5 µm (P < 0.001); and inferotemporal = 143.2 µm, 143.6 µm (P = 0.51). Longer axial length was associated with thinner RNFL globally, nasally, inferotemporally, superotemporally, superonasally, and inferonasally, as well as thicker RNFL temporally. The prevalence of ONL and BL classifications was generally higher than the expected rates of 1% and 4%, respectively, in temporal sectors and lower than expected in nasal sectors. The prevalence of global BL classifications was lower than expected (right eye, 2.3%; left eye, 2.6%). Conclusions: Measured RNFL thickness differs with axial length and between right and left eyes. More reference data are needed to better define the normal limits of RNFL variation in different populations. Translational Relevance: This study provides an improved understanding of normal variation in RNFL thickness in young adults.

Details

ISSN :
21642591
Volume :
10
Database :
OpenAIRE
Journal :
Translational Vision Science & Technology
Accession number :
edsair.doi.dedup.....52833f2baa2ba57602b07e692db58b36
Full Text :
https://doi.org/10.1167/tvst.10.9.3