- Visualization of the left atrium (LA) and pulmonary veins (PVs) is crucial in PV isolation (PVI). Additional delineation of the esophagus might avoid severe side effects. Cardiac C-arm computed tomography (DynaCT Cardiac, Siemens AG, Forchheim, Germany) has been introduced as a novel intraprocedural imaging modality based on a rotational angiography.The purpose of this study was to prove the quantitative accuracy of DynaCT Cardiac as compared with multislice CT (MSCT) in imaging of the LA and PV in patients undergoing PVI.Thirty-four consecutive patients (22 male, age 64 +/- 12 years) with symptomatic atrial fibrillation (AF) and indication for PVI were studied. Diameters of the PV, the LA appendage (LAA), and the descending aorta were measured, and the position of the esophagus was defined using preprocedural MSCT and intraprocedural DynaCT Cardiac.There was a significant correlation between both measurements for diameters of the LAA (r = 0.86, P.05), PV (r = 0.98, P.05), and the descending aorta (r = 0.98, P.05). The overall correlation of vessel diameters was r = 0.99. The LA volumes correlation was r = 0.86 and P.05. A significant difference of the esophageal position was found between preprocedural MSCT and intraprocedural DynaCT Cardiac (r = 0.53, P.05).DynaCT Cardiac is a novel intraprocedural rotational angiographic technique. It is highly accurate in displaying crucial structures for PVI in comparison with the results of MSCT. Therefore, DynaCT Cardiac can be used as an alternative imaging technique to improve PVI accuracy.
- Subjects :
- Male
medicine.medical_specialty
medicine.medical_treatment
Ablation of atrial fibrillation
Catheter ablation
Computed tomography
Intraoperative Period
Esophagus
Imaging, Three-Dimensional
Left atrial
Physiology (medical)
medicine.artery
Atrial Fibrillation
Medicine
Humans
Heart Atria
Retrospective Studies
medicine.diagnostic_test
business.industry
Reproducibility of Results
Atrial fibrillation
Middle Aged
medicine.disease
medicine.anatomical_structure
Rotational angiography
Descending aorta
Fluoroscopy
cardiovascular system
Catheter Ablation
Female
Radiology
Cardiology and Cardiovascular Medicine
business
Tomography, X-Ray Computed
Subjects
Details
- ISSN :
- 15563871
- Volume :
- 5
- Issue :
- 12
- Database :
- OpenAIRE
- Journal :
- Heart rhythm
- Accession number :
- edsair.doi.dedup.....522814a8ba4a1d27a7ed4b2e39b14376