- BACKGROUND Intraoperative flash stimulation visual evoked potential (VEP) monitoring has been used for endoscopic endonasal approach (EEA). Recently, off-response VEP, which is recorded when the light stimulus is turned off, was introduced to monitor visual function intraoperatively. OBJECTIVE To evaluate off-response VEP monitoring in comparison with the conventional flash stimulation VEP monitoring for EEA. METHODS From March 2015 to March 2020, 70 EEA surgeries with intraoperative VEP monitoring (140 eyes) were performed. Light stimuli were delivered by a pair of goggle electrodes. Recording electrodes were placed on the scalp over the occipital region. The warning signal was prompted by a reduction of the peak-to-peak amplitude of the VEP by more than 50% compared to the initial amplitude. Visual function was assessed pre- and postoperatively. Results of flash and off-response VEP monitoring were compared. RESULTS VEP was recorded in 134 eyes. Warning signal occurred in 23 eyes (transient in 17 eyes and permanent in 6 eyes). Two eyes showed permanent VEP attenuation for flash VEP monitoring, in which one patient had postoperative visual function deterioration. Four eyes showed permanent VEP attenuation for off-response VEP monitoring, where 2 patients had postoperative visual function deterioration. Sensitivity, specificity, positive predictive value, and negative predictive value were 100%, 98.9%, 50%, and 100%, respectively, for flash stimulation VEP, and 100%, 97.8%, 50%, and 100%, respectively, for off-response VEP. CONCLUSION VEP monitoring was useful to monitor visual function in EEA surgery. Off-response VEP monitoring was not inferior to conventional flash stimulation VEP monitoring.
- Subjects :
- Neurologic Examination
medicine.medical_specialty
genetic structures
Endoscopic endonasal surgery
Eye Diseases
business.industry
Flash vep
Endoscopy
Occipital region
Flash (photography)
medicine.anatomical_structure
Ophthalmology
Scalp
Monitoring, Intraoperative
medicine
Evoked Potentials, Visual
Humans
Surgery
Neurology (clinical)
Off response
Evoked potential
business
Intraoperative neurophysiological monitoring
Subjects
Details
- ISSN :
- 23324260
- Volume :
- 21
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Operative neurosurgery (Hagerstown, Md.)
- Accession number :
- edsair.doi.dedup.....5128d3c0a9ea7a68f860d93012bd6fbf