Back to Search
Start Over
Radiomics analysis of multicenter CT images for discriminating mucinous adenocarcinoma from nomucinous adenocarcinoma in rectal cancer and comparison with conventional CT values
- Source :
- Journal of X-Ray Science and Technology. 28:285-297
- Publication Year :
- 2020
- Publisher :
- IOS Press, 2020.
-
Abstract
- Objective To investigate the value of CT-based radiomics signature for preoperatively discriminating mucinous adenocarcinoma (MA) from nomucinous adenocarcinoma (NMA) in rectal cancer and compare with conventional CT values. Method A total of 225 patients with histologically confirmed MA or NMA of rectal cancer were retrospectively enrolled. Radiomics features were computed from the entire tumor volume segmented from the post-contrast phase CT images. The maximum relevance and minimum redundancy (mRMR) and LASSO regression model were performed to select the best preforming features and build the radiomics models using a training cohort of 155 cases. Then, predictive performance of the models was validated using a validation cohort of 70 cases and receiver operating characteristics (ROC) analysis method. Meanwhile, CT values in post- and pre-contrast phase, as well as their difference (D-values) of tumors in two cohorts were measured by two radiologists. ROC curves were also calculated to assess diagnostic efficacies. Results One hundred and sixty-three patients were confirmed by pathology as NMA and 62 cases were MA. The radiomics signature comprised 19 selected features and showed good discrimination performance in both the training and validation cohorts. The areas under ROC curves (AUC) are 0.93 (95% confidence interval [CI]: 0.89-0.98) in training cohort and 0.93 (95% CI: 0.87-0.99) in validation cohort, respectively. Three sets of CT values of MA in pre- and post-contrast phase, and their difference (D-value) (31±7.0, 51±12.6 and 20±9.3, respectively) were lower than those of NMA (37±5.6, 69±13.3 and 32±11.7, respectively). Comparing to the radiomics signature, using three sets of conventional CT values yielded relatively low diagnostic performance with AUC of 0.84 (95% CI: 0.78-0.88), 0.75 (95% CI: 0.69-0.81) and 0.78 (95% CI: 0.72-0.83), respectively. Conclusion This study demonstrated that CT radiomics features could be utilized as a noninvasive biomarker to identify MA patients from NMA of rectal cancer preoperatively, which is more accurate than using the conventional CT values.
- Subjects :
- Male
Colorectal cancer
Adenocarcinoma
Cohort Studies
Diagnosis, Differential
Lasso regression
Radiomics
Humans
Medicine
Radiology, Nuclear Medicine and imaging
Electrical and Electronic Engineering
Instrumentation
Retrospective Studies
Noninvasive biomarkers
Radiation
Receiver operating characteristic
Rectal Neoplasms
business.industry
Rectum
Middle Aged
Condensed Matter Physics
medicine.disease
Adenocarcinoma, Mucinous
Training cohort
Confidence interval
Female
Tomography, X-Ray Computed
business
Nuclear medicine
Subjects
Details
- ISSN :
- 10959114 and 08953996
- Volume :
- 28
- Database :
- OpenAIRE
- Journal :
- Journal of X-Ray Science and Technology
- Accession number :
- edsair.doi.dedup.....509b97ce764674928eb796b5bc18a1f9
- Full Text :
- https://doi.org/10.3233/xst-190614