Back to Search Start Over

High voltage testing for the Majorana Demonstrator

Authors :
Ralph Massarczyk
A. Galindo-Uribarri
Yuen-Dat Chan
S. Vasilyev
A. Li
A. Thompson
Alan Poon
N. Abgrall
Anne-Marie Suriano
J. A. Detwiler
Z. Fu
F. E. Bertrand
R. D. Martin
J. Gruszko
J. Goett
J. F. Wilkerson
R. G. H. Robertson
M. A. Howe
E. Romero-Romero
D. J. Tedeschi
B. R. White
C.M. O'Shaughnessy
Stanley M. Howard
Jonathan D. Leon
I. S. Guinn
F. T. Avignone
R. L. Varner
B. R. Jasinski
M. P. Green
M. Buuck
C. Wiseman
Reyco Henning
Eric W. Hoppe
C. Cuesta
J. Rager
D. Byram
Matthew Busch
Y.-U. Efremenko
P. J. Doe
C.-H. Yu
H. Ejiri
A. S. Barabash
Susanne Mertens
A. W. Bradley
V. Yumatov
K. J. Keeter
V.B. Brudanin
B. Shanks
V. E. Guiseppe
S. R. Elliott
Brian D. LaFerriere
D. C. Radford
A. S. Caldwell
Keith Rielage
M. Shirchenko
John L. Orrell
J. MacMullin
Kai Vetter
S. J. Meijer
C. D. Christofferson
K. Vorren
K. T. Ton
M. F. Kidd
E. Yakushev
C. Dunagan
S. I. Konovalov
W. Xu
G. K. Giovanetti
J. E. Trimble
Pinghan Chu
Richard T. Kouzes
I. J. Arnquist
N. Snyder
Source :
Abgrall, N; Arnquist, IJ; Avignone, FT; Barabash, AS; Bertrand, FE; Bradley, AW; et al.(2016). High voltage testing for the Majorana Demonstrator. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 823, 83-90. doi: 10.1016/j.nima.2016.04.006. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/1xh8n5b7
Publication Year :
2016
Publisher :
Elsevier BV, 2016.

Abstract

The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge effects during the MAJORANA Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.<br />9 pages, 12 figures, 8 tables, submitted to NIM A

Details

ISSN :
01689002
Volume :
823
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi.dedup.....5026b226f73ad17e3390ddce03333e87