Back to Search
Start Over
Dosimetric study of current treatment options for radiotherapy in retinoblastoma
- Source :
- International journal of radiation oncology, biology, physics. 82(3)
- Publication Year :
- 2010
-
Abstract
- Purpose To determine the best treatment technique for patients with retinoblastoma requiring radiotherapy to the whole eye. Methods and Materials Treatment plans for 3 patients with retinoblastoma were developed using 10 radiotherapy techniques including electron beams, photon beam wedge pair (WP), photon beam three-dimensional conformal radiotherapy (3D-CRT), fixed gantry intensity-modulated radiotherapy (IMRT), photon volumetric arc therapy (VMAT), fractionated stereotactic radiotherapy, and helical tomotherapy (HT). Dose-volume analyses were carried out for each technique. Results All techniques provided similar target coverage; conformity was highest for VMAT, nine-field (9F) IMRT, and HT (conformity index [CI] = 1.3) and lowest for the WP and two electron techniques (CI = 1.8). The electron techniques had the highest planning target volume dose gradient (131% of maximum dose received [D max ]), and the CRT techniques had the lowest (103% D max ) gradient. The volume receiving at least 20 Gy (V 20Gy ) for the ipsilateral bony orbit was lowest for the VMAT and HT techniques (56%) and highest for the CRT techniques (90%). Generally, the electron beam techniques were superior in terms of brain sparing and delivered approximately one-third of the integral dose of the photon techniques. Conclusions Inverse planned image-guided radiotherapy delivered using HT or VMAT gives better conformity index, improved orbital bone and brain sparing, and a lower integral dose than other techniques.
- Subjects :
- Organs at Risk
Cancer Research
medicine.medical_specialty
medicine.medical_treatment
Radiography
Retinal Neoplasms
Planning target volume
Electrons
Radiosurgery
Tomotherapy
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Radiation treatment planning
Radiation Injuries
Photons
Radiation
business.industry
Retinoblastoma
Radiotherapy Planning, Computer-Assisted
Treatment options
Brain
Infant
Radiotherapy Dosage
medicine.disease
Radiation therapy
Oncology
Integral dose
Child, Preschool
Radiology
Radiotherapy, Intensity-Modulated
Radiotherapy, Conformal
business
Nuclear medicine
Orbit
Organ Sparing Treatments
Radiotherapy, Image-Guided
Subjects
Details
- ISSN :
- 1879355X
- Volume :
- 82
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- International journal of radiation oncology, biology, physics
- Accession number :
- edsair.doi.dedup.....4e60c5ec1b3ec2ecc524c9bea6d29bda