Back to Search
Start Over
Influence of MRI-based bone outline definition errors on external radiotherapy dose calculation accuracy in heterogeneous pseudo-CT images of prostate cancer patients
- Source :
- Tampere University
- Publication Year :
- 2014
-
Abstract
- This work evaluates influences of susceptibility-induced bone outline shift and perturbations, and bone segmentation errors on external radiotherapy dose calculation accuracy in magnetic resonance imaging (MRI)-based pseudo-computed tomography (CT) images of the male pelvis.T₁/T₂*-weighted fast gradient echo, T₁-weighted spin echo and T₂-weighted fast spin echo images were used in bone detection investigation. Bone edge location and bone diameter in MRI were evaluated by comparing those in the images with actual physical measurements of fresh deer bones positioned in a gelatine phantom. Dose calculation accuracy in pseudo-CT images was investigated for 15 prostate cancer patients. Bone outlines in T₁/T₂*-weighted images were contoured and additional segmentation errors were simulated by expanding and contracting the bone contours with 1 mm spacing. Heterogeneous pseudo-CT images were constructed by adopting a technique transforming the MRI intensity values into Hounsfield units with separate conversion models within and outside of bone segment.Bone edges and diameter in the phantom were illustrated correctly within a 1 mm-pixel size in MRI. Each 1 mm-sized systematic error in bone segment resulted in roughly 0.4% change to the prostate dose level in the pseudo-CT images. The prostate average (range) dose levels in pseudo-CT images with additional systematic bone segmentation errors of -2 mm, 0 mm and 2 mm were 0.5% (-0.5-1.4%), -0.2% (-1.0-0.7%), and -0.9% (-1.8-0.0%) compared to those in CT images, respectively, in volumetric modulated arc therapy treatment plans calculated by Monte Carlo algorithm.Susceptibility-induced bone outline shift and perturbations do not result in substantial uncertainty for MRI-based dose calculation. Dose consistency of 2% can be achieved reliably for the prostate if heterogeneous pseudo-CT images are constructed with ≤± 2 mm systematic error in bone segment.
- Subjects :
- Male
Imaging phantom
Medicine
Animals
Humans
Radiology, Nuclear Medicine and imaging
Femur
Segmentation
medicine.diagnostic_test
Tibia
business.industry
Phantoms, Imaging
Deer
Prostatic Neoplasms
Magnetic resonance imaging
Radiotherapy Dosage
Hematology
General Medicine
Magnetic Resonance Imaging
Intensity (physics)
Oncology
Connective Tissue
Spin echo
Tomography
Anatomic Landmarks
business
Nuclear medicine
Tomography, X-Ray Computed
Correction for attenuation
Subjects
Details
- ISSN :
- 1651226X
- Volume :
- 53
- Issue :
- 8
- Database :
- OpenAIRE
- Journal :
- Acta oncologica (Stockholm, Sweden)
- Accession number :
- edsair.doi.dedup.....4e4e4a7a6b583034b6395d4bdf93d4e3