Back to Search Start Over

Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial

Authors :
Håkan Norén
Per Olofsson
Anna-Karin Sundström
Charlotte Hellsten
Ingemar Kjellmer
Maivi Månsson
Laila Mårtensson
Andreas Herbst
Henrik Hagberg
Isis Amer-Wåhlin
Håkan Lilja
Claes Lindoff
Karel Marsal
Source :
The Lancet. 358:534-538
Publication Year :
2001
Publisher :
Elsevier BV, 2001.

Abstract

BACKGROUND: Previous studies indicate that analysis of the ST waveform of the fetal electrocardiogram provides information on the fetal response to hypoxia. We did a multicentre randomised controlled trial to test the hypothesis that intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis results in an improved perinatal outcome compared with cardiotocography alone. METHODS: At three Swedish labour wards, 4966 women with term fetuses in the cephalic presentation entered the trial during labour after a clinical decision had been made to apply a fetal scalp electrode for internal cardiotocography. They were randomly assigned monitoring with cardiotocography plus ST analysis (CTG+ST group) or cardiotocography only (CTG group). The main outcome measure was rate of umbilical-artery metabolic acidosis (pH 12 mmol/L). Secondary outcomes included operative delivery for fetal distress. Results were first analysed according to intention to treat, and secondly after exclusion of cases with severe malformations or with inadequate monitoring. FINDINGS: The CTG+ST group showed significantly lower rates of umbilical-artery metabolic acidosis than the cardiotocography group (15 of 2159 [0.7%] vs 31 of 2079 [2%], relative risk 0.47 [95% CI 0.25-0.86], p=0.02) and of operative delivery for fetal distress (193 of 2519 [8%] vs 227 of 2447 [9%], 0.83 [0.69-0.99], p=0.047) when all cases were included according to intention to treat. The differences were more pronounced after exclusion of 291 in the CTG+ST group and 283 in the CTG group with malformations or inadequate recording. INTERPRETATION: Intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis increases the ability of obstetricians to identify fetal hypoxia and to intervene more appropriately, resulting in an improved perinatal outcome.

Details

ISSN :
01406736
Volume :
358
Database :
OpenAIRE
Journal :
The Lancet
Accession number :
edsair.doi.dedup.....4e1e24b02975e2f6d033b8de0d194778