Back to Search
Start Over
Segment Length in Cine Strain Analysis Predicts Cardiac Resynchronization Therapy Outcome Beyond Current Guidelines
- Source :
- Zweerink, A, Friedman, D J, Klem, I, van de Ven, P M, Vink, C, Biesbroek, P S, Hansen, S M, Kim, R J, van Rossum, A C, Atwater, B D, Allaart, C P & Nijveldt, R 2021, ' Segment Length in Cine Strain Analysis Predicts Cardiac Resynchronization Therapy Outcome Beyond Current Guidelines ', Circulation. Cardiovascular Imaging, vol. 14, no. 7, e012350, pp. 607-617 . https://doi.org/10.1161/CIRCIMAGING.120.012350, Zweerink, A, Friedman, D J, Klem, I, van de Ven, P M, Vink, C, Biesbroek, P S, Hansen, S M, Kim, R J, van Rossum, A C, Atwater, B D, Allaart, C P & Nijveldt, R 2021, ' Segment length in cine strain analysis predicts cardiac resynchronization therapy outcome beyond current guidelines ', Circulation: Cardiovascular Imaging, pp. 607-617 . https://doi.org/10.1161/CIRCIMAGING.120.012350, Circulation: Cardiovascular Imaging, 607-617, STARTPAGE=607;ENDPAGE=617;ISSN=1941-9651;TITLE=Circulation: Cardiovascular Imaging, Circulation-Cardiovascular Imaging, 14, 7, Circulation-Cardiovascular Imaging, 14
- Publication Year :
- 2021
-
Abstract
- Background: Patients with a class I recommendation for cardiac resynchronization therapy (CRT) are likely to benefit, but the effect of CRT in class II patients is more heterogeneous and additional selection parameters are needed in this group. The recently validated segment length in cine strain analysis of the septum (SLICE-ESS sep ) measurement on cardiac magnetic resonance cine imaging predicts left ventricular functional recovery after CRT but its prognostic value is unknown. This study sought to evaluate the prognostic value of SLICE-ESS sep for clinical outcome after CRT. Methods: Two hundred eighteen patients with a left bundle branch block or intraventricular conduction delay and a class I or class II indication for CRT who underwent preimplantation cardiovascular magnetic resonance examination were enrolled. SLICE-ESS sep was manually measured on standard cardiovascular magnetic resonance cine imaging. The primary combined end point was all-cause mortality, left ventricular assist device, or heart transplantation. Secondary end points were (1) appropriate implantable cardioverter defibrillator therapy and (2) heart failure hospitalization. Results: Two-thirds (65%) of patients had a positive SLICE-ESS sep ≥0.9% (ie, systolic septal stretching). During a median follow-up of 3.8 years, 66 (30%) patients reached the primary end point. Patients with positive SLICE-ESS sep were at lower risk to reach the primary end point (hazard ratio 0.36; P P =0.019), but not for implantable cardioverter defibrillator therapy (hazard ratio, 0.66; P =0.272). Clinical outcome of class II patients with a positive ESS sep was similar to those of class I patients (hazard ratio, 1.38 [95% CI, 0.66–2.88]; P =0.396). Conclusions: Strain assessment of the septum (SLICE-ESS sep ) provides a prognostic measure for clinical outcome after CRT. Detection of a positive SLICE-ESS sep in patients with a class II indication predicts improved CRT outcome similar to those with a class I indication whereas SLICE-ESS sep negative patients have poor prognosis after CRT implantation.
- Subjects :
- Heart transplantation
medicine.medical_specialty
Cardiac resynchronization therapy
business.industry
medicine.medical_treatment
Vascular damage Radboud Institute for Health Sciences [Radboudumc 16]
Segment length
Heart failure
030204 cardiovascular system & hematology
medicine.disease
Prognosis
030218 nuclear medicine & medical imaging
03 medical and health sciences
Defibrillator
0302 clinical medicine
Internal medicine
Cardiology
medicine
Radiology, Nuclear Medicine and imaging
Implantable
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- Language :
- English
- ISSN :
- 19419651
- Database :
- OpenAIRE
- Journal :
- Zweerink, A, Friedman, D J, Klem, I, van de Ven, P M, Vink, C, Biesbroek, P S, Hansen, S M, Kim, R J, van Rossum, A C, Atwater, B D, Allaart, C P & Nijveldt, R 2021, ' Segment Length in Cine Strain Analysis Predicts Cardiac Resynchronization Therapy Outcome Beyond Current Guidelines ', Circulation. Cardiovascular Imaging, vol. 14, no. 7, e012350, pp. 607-617 . https://doi.org/10.1161/CIRCIMAGING.120.012350, Zweerink, A, Friedman, D J, Klem, I, van de Ven, P M, Vink, C, Biesbroek, P S, Hansen, S M, Kim, R J, van Rossum, A C, Atwater, B D, Allaart, C P & Nijveldt, R 2021, ' Segment length in cine strain analysis predicts cardiac resynchronization therapy outcome beyond current guidelines ', Circulation: Cardiovascular Imaging, pp. 607-617 . https://doi.org/10.1161/CIRCIMAGING.120.012350, Circulation: Cardiovascular Imaging, 607-617, STARTPAGE=607;ENDPAGE=617;ISSN=1941-9651;TITLE=Circulation: Cardiovascular Imaging, Circulation-Cardiovascular Imaging, 14, 7, Circulation-Cardiovascular Imaging, 14
- Accession number :
- edsair.doi.dedup.....4c051b9b69327c26a8a41a427f053eb1
- Full Text :
- https://doi.org/10.1161/CIRCIMAGING.120.012350