Back to Search Start Over

The IN.PACT DEEP clinical drug-coated balloon trial 5-year outcomes

Authors :
Zeller, Thomas
Micari, Antonio
Scheinert, Dierk
Baumgartner, Iris
Bosiers, Marc
Vermassen, Frank E G
Banyai, Martin
Shishehbor, Mehdi H
Wang, Hong
Brodmann, Marianne
​Robotics and image-guided minimally-invasive surgery (ROBOTICS)
Source :
JACC-CARDIOVASCULAR INTERVENTIONS, Zeller, Thomas; Micari, Antonio; Scheinert, Dierk; Baumgartner, Iris; Bosiers, Marc; Vermassen, Frank E G; Banyai, Martin; Shishehbor, Mehdi H; Wang, Hong; Brodmann, Marianne (2020). The IN.PACT DEEP Clinical Drug-Coated Balloon Trial: 5-Year Outcomes. JACC. Cardiovascular Interventions, 13(4), pp. 431-443. Elsevier 10.1016/j.jcin.2019.10.059 , Jacc-Cardiovascular interventions, 13(4), 431-443. ELSEVIER SCIENCE INC
Publication Year :
2020

Abstract

OBJECTIVES The goal of this study was to evaluate the 5-year follow-up data of the IN.PACT DEEP (Randomized IN.PACT Amphirion Drug-Coated Balloon [DCB] vs. Standard Percutaneous Transluminal Angioplasty [PTA] for the Treatment of Below-the-Knee Critical Limb Ischemia [CLI]) trial. BACKGROUND Initial studies from randomized controlled trials have shown comparable short-term outcomes of DCB angioplasty versus PTA in patients with CLI with infrapopliteal disease. However, the long-term safety and effectiveness of DCB angioplasty remain unknown in this patient population. METHODS IN.PACT DEEP was an independently adjudicated prospective, multicenter, randomized controlled trial that enrolled 358 subjects with CLI. Subjects were randomized 2:1 to DCB angioplasty or PTA. Assessments through 5 years included freedom from clinically driven target lesion revascularization, amputation, and all-cause death. Additional assessments were conducted to identify risk factors for death and major amputation, including paclitaxel dose tercile. RESULTS Freedom from clinically driven target lesion revascularization through 5 years was 70.9% and 76.0% (log-rank p = 0.406), and the incidence of the safety composite endpoint was 59.8% and 57.5% (log-rank p = 0.309) in the DCB angioplasty and PTA groups, respectively. The rate of major amputation was 15.4% for DCB angioplasty compared with 10.6% for PTA (log-rank p = 0.108). Given the recent concern regarding a late mortality signal in patients treated with paclitaxel-coated devices, additional analyses from this study showed no increase in all-cause mortality with DCB angioplasty (39.4%) compared with PTA (44.9%) (log-rank p = 0.727). Predictors of mortality included age, Rutherford category >4, and previous revascularization but not paclitaxel by dose tercile. CONCLUSIONS Tibial artery revascularization in patients with CLI using DCB angioplasty resulted in comparable long-term safety and effectiveness as PTA. Paclitaxel exposure was not related to increased risk for amputation or all-cause mortality at 5-year follow-up. (Study of IN.PACT Amphirion (R) Drug Eluting Balloon vs. Standard PTA for the Treatment of Below the Knee Critical Limb Ischemia [INPACT-DEEP]; NCT00941733) (C) 2020 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.

Details

Language :
English
ISSN :
19368798 and 18767605
Database :
OpenAIRE
Journal :
JACC-CARDIOVASCULAR INTERVENTIONS, Zeller, Thomas; Micari, Antonio; Scheinert, Dierk; Baumgartner, Iris; Bosiers, Marc; Vermassen, Frank E G; Banyai, Martin; Shishehbor, Mehdi H; Wang, Hong; Brodmann, Marianne (2020). The IN.PACT DEEP Clinical Drug-Coated Balloon Trial: 5-Year Outcomes. JACC. Cardiovascular Interventions, 13(4), pp. 431-443. Elsevier 10.1016/j.jcin.2019.10.059 <http://dx.doi.org/10.1016/j.jcin.2019.10.059>, Jacc-Cardiovascular interventions, 13(4), 431-443. ELSEVIER SCIENCE INC
Accession number :
edsair.doi.dedup.....4bd85fd394475679177d2a8cfec9f24d