Back to Search
Start Over
The effect of muscle-tendon unit vs. fascicle analyses on vastus lateralis force-generating capacity during constant power output cycling with variable cadence
- Source :
- Journal of Applied Physiology. 124:993-1002
- Publication Year :
- 2018
- Publisher :
- American Physiological Society, 2018.
-
Abstract
- The maximum force-generating capacity of a muscle is dependent on the lengths and velocities of its contractile apparatus. Muscle-tendon unit (MTU) length changes can be estimated from joint kinematics; however, contractile element length changes are more difficult to predict during dynamic contractions. The aim of this study was to compare vastus lateralis (VL) MTU and fascicle level force-length and force-velocity relationships, and dynamic muscle function while cycling at a constant submaximal power output (2.5 W/kg) with different cadences. We hypothesized that manipulating cadence at a constant power output would not affect VL MTU shortening, but significantly affect VL fascicle shortening. Furthermore, these differences would affect the predicted force capacity of the muscle. Using an isokinetic dynamometer and B-mode ultrasound (US), we determined the force-length and force-velocity properties of the VL MTU and its fascicles. In addition, three-dimensional kinematics and kinetics of the lower limb, as well as US images of VL fascicles were collected during submaximal cycling at cadences of 40, 60, 80, and 100 rotations per minute. Ultrasound measures revealed a significant increase in fascicle shortening as cadence decreased (84% increase across all conditions, P < 0.01), whereas there were no significant differences in MTU lengths across any of the cycling conditions (maximum of 6%). The MTU analysis resulted in greater predicted force capacity across all conditions relative to the force-velocity relationship ( P < 0.01). These results reinforce the need to determine muscle mechanics in terms of separate contractile element and connective tissue length changes during isokinetic contractions, as well as dynamic movements like cycling.NEW & NOTEWORTHY We demonstrate that vastus lateralis (VL) muscle tendon unit (MTU) length changes do not adequately reflect the underlying fascicle mechanics during cycling. When examined across different pedaling cadence conditions, the force-generating potential measured only at the level of MTU (or joint) overestimated the maximum force capacity of VL compared with analysis using fascicle level data.
- Subjects :
- Adult
030110 physiology
0301 basic medicine
Physiology
Muscle Strength Dynamometer
Quadriceps Muscle
Tendons
RC1200
Young Adult
03 medical and health sciences
0302 clinical medicine
Physiology (medical)
medicine
Humans
Physics
Muscle mechanics
030229 sport sciences
Fascicle
Generating capacity
Bicycling
Tendon
medicine.anatomical_structure
Constant power
Cycling
Cadence
Biomedical engineering
Subjects
Details
- ISSN :
- 15221601 and 87507587
- Volume :
- 124
- Database :
- OpenAIRE
- Journal :
- Journal of Applied Physiology
- Accession number :
- edsair.doi.dedup.....4bca44e8751bc994577716584f02a582
- Full Text :
- https://doi.org/10.1152/japplphysiol.00356.2017