Back to Search
Start Over
Study on the effect of different blood flow velocities of pulmonary vein on endocardial microwave ablation of atrial fibrillation
- Source :
- Technology and Health Care. 30:29-41
- Publication Year :
- 2021
- Publisher :
- IOS Press, 2021.
-
Abstract
- OBJECTIVE: To cure atrial fibrillation, the maximum ablation depth (⩾ 50∘C) should exceed the myocardial thickness to achieve the effect of transmural ablation. The blood flow of pulmonary vein in the endocardium can cause the change in the myocardial temperature distribution. Therefore, the study investigated the effect of different pulmonary vein blood flow velocities on the endocardial microwave ablation. METHODS: The finite element model of the endocardial microwave ablation of pulmonary vein was simulated by electromagnetic thermal flow coupling. The ablation power was 30 W and the ablation time was within 30 s. The blood flow in the coupling of fluid mechanics equation and heat transfer equation results in the heat damage. Furthermore, the cause of the different lesion dimensions is the blood flow velocity. The flow velocities were set as 0, 0.02, 0.05, 0.07, 0.12, 0.16, 0.20, 0.25 and 0.30 m/s. RESULTS: When the flow velocities were 0, 0.02, 0.05, 0.07, 0.12, 0.16, 0.20, 0.25 and 0.30 m/s, the maximum ablation depth were 6.00, 5.56, 5.16, 5.12, 5.04, 5.01, 4.98, 4.96 and 4.94 mm, respectively; the maximum ablation width were 12.53, 9.63, 9.23, 9.16, 9.07, 9.05, 8.94, 8.91 and 8.90 mm, respectively; the maximum ablation length were 12.00, 11.61, 8.98, 8.59, 8.37, 8.23, 8.16, 8.06 and 8.04 mm respectively. To achieve transmural ablation, the time was 3, 3, 3, 3, 3, 4, 4, 4, 4 s, respectively when the myocardial thickness was 2 mm; the time was 7, 8, 8, 8, 9, 9, 9, 9, 9 s, respectively when 3 mm; the time was 15, 16, 18, 19, 19, 20, 20, 20, 20 s, respectively when 4 mm. CONCLUSIONS: When the velocity increases from 0 m/s to 0.3 m/s, the microwave lesion depth decreases by 1.06 mm. To achieve transmural ablation, when the myocardial thickness is 2 mm, 3 and 4 s should be taken when the velocity is 0–0.12 and 0.12–0.30 m/s, respectively; when the myocardial thickness is 3 mm, 7, 8 and 9 s should be taken when 0, 0–0.07 and 0.07–0.30 m/s respectively; when the myocardial thickness is 4 mm, 15, 16, 18, 19, 20 s should be taken when 0, 0–0.02, 0.02–0.05, 0.05–0.12, 0.12 m/s–0.30 m/s.
- Subjects :
- Materials science
medicine.medical_treatment
Biomedical Engineering
Biophysics
Health Informatics
Bioengineering
Pulmonary vein
Biomaterials
Atrial Fibrillation
medicine
Humans
Microwaves
Endocardium
Microwave ablation
Fluid mechanics
Atrial fibrillation
Blood flow
medicine.disease
Lesion depth
Ablation
Pulmonary Veins
Catheter Ablation
Blood Flow Velocity
Information Systems
Biomedical engineering
Subjects
Details
- ISSN :
- 18787401 and 09287329
- Volume :
- 30
- Database :
- OpenAIRE
- Journal :
- Technology and Health Care
- Accession number :