Back to Search Start Over

Severe Tortuosity of the Distal Descending Thoracic Aorta Affects the Accuracy of Distal Deployment During a Thoracic Endovascular Aortic Repair

Authors :
Tomohiro Sato
Hiroshi Banno
Shuta Ikeda
Yohei Kawai
Takuya Tsuruoka
Masayuki Sugimoto
Kiyoaki Niimi
Akio Kodama
Kimihiro Komori
Source :
Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.
Publication Year :
2022

Abstract

Purpose: An accurate distal deployment is essential for successful thoracic endovascular aortic repair (TEVAR) of a paradiaphragmatic aortic aneurysm. This study aimed to investigate the anatomical and intraoperative factors that affect the accuracy of distal deployment during TEVAR. Methods: We conducted a retrospective review of preoperative and postoperative computed tomography scans of 426 patients undergoing TEVAR at our institution between October 2008 and May 2021, of which the stent-graft was attempted to be deployed just above the celiac axis or the superior mesenteric artery in 56 patients. Based on the anatomical factors related to the malposition (deployed >10 mm away from the target vessel) and the greater curve to the straight-line ratio (G/S ratio), the patients were categorized as severe tortuosity (n=21) and mild tortuosity (n=35) groups to compare the operative and clinical outcomes. Result: Stent-graft malpositioning occurred in 21 cases. Among all anatomical variables, only the G/S ratio was significantly larger in the malpositioned cases (p=0.049). A cutoff G/S ratio value of 1.15 was determined using the receiver operating curve analysis. In the severe tortuosity group, the distal end of the stent-graft was significantly farther (median: 10.0 [interquartile range (IQR): 2.5–19.5] mm vs 3.0 [0–8.0] mm; p=0.015) from the target vessel, and the tilt angle of the stent-graft’s distal edge was larger (median: 21.4 [IQR: 15.8–24.5] vs 9.5 [5.5–12.5] degree; pConclusion: Severe tortuosity in the distal descending thoracic aorta is associated with a malpositioned and tilted distal end of the stent-graft. Clinical Impact Thoracic endovascular aortic repair (TEVAR) for paradiaphragmatic thoracic aortic aneurysms requires accurate distal landing. In this paper, a retrospective CT analysis revealed that the greater curve to the straight-line ratio (G/S ratio) was associated to affects the malposition of the stent graft, defined as being deployed more than 10 mm away from the target vessel. Further, a comparative analysis based on the G/S ratio demonstrated that severe aortic tortuosity was associated with a more distal and tilted deployment of the stent graft.

Details

ISSN :
15451550
Database :
OpenAIRE
Journal :
Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
Accession number :
edsair.doi.dedup.....4ae26d86e8d8ccc417be4087a582a7de