Back to Search
Start Over
The pursuit of normal reference values of pancreas stiffness by using Acoustic Radiation Force Impulse (ARFI) elastography
- Source :
- Medical ultrasonography. 18(4)
- Publication Year :
- 2016
-
Abstract
- Aim: The purpose of this study is to evaluate pancreatic stiffness by ARFI abdominal elastography. In the current literature, there are relatively few studies that have assessed the clinical utility of this technique. Material and method: A number of 37 healthy subjects were included. The data were collected in a prospective manner and afterwards included in an observational, analytical and longitudinal study. Subsequently viewing the pancreatic parenchyma in bidimensional mode (2D-US) mode, 10 shear wave velocity (SWV) measurements for each segment: head, body and tail were performed. Statistical analysis by regression models targeted also the possible influence of other factors in assessing SWV. A comparative analysis was performed regarding the statistical significance of 5 versus 10 SWV measurements for each segment. Results: The pancreas was entirely evaluated in all subjects. The mean SWV from the entire parenchyma was 1.216 m/s±0.36 and between the three segments SWV were similar (head: 1.224 m/s, body: 1.227 m/s and tail: 1.191 m/s). A ratio of the IQR/Median >0.4 was interpreted as statistically invalid, relevant data being highlighted in the percentage of 83.78% for the head of the pancreas, 78.37% for the body, and 67.56% at the caudal level. Significant correlations were observed between the data (mean and median SWV) provided by the group with 5 measurements of the SWV versus the standard group: 93.9% for the head, 96.6% for the body, and 98.7% accordingly to the tail. Conclusions: SWV determination by percutaneous approach represents a useful imaging method for evaluating pancreatic stiffness, of course within these limitations. Because we did not observe statistically significant differences between the results obtained by 5 or 10 measurements, we suggest that it would be sufficient to perform only five measurements of the SWV per pancreatic segment. The data obtained in the normal pancreas could be used in future comparative assessments regarding the inflammatory or tumoral pathology of the pancreas.
- Subjects :
- Adult
Male
Acoustics and Ultrasonics
Impulse (physics)
Sensitivity and Specificity
030218 nuclear medicine & medical imaging
Arfi elastography
03 medical and health sciences
Young Adult
0302 clinical medicine
Pregnancy
Reference Values
Statistical significance
Elastic Modulus
Tensile Strength
Image Interpretation, Computer-Assisted
medicine
Humans
Radiology, Nuclear Medicine and imaging
Longitudinal Studies
Acoustic radiation force
Pancreas
Radiological and Ultrasound Technology
medicine.diagnostic_test
business.industry
Romania
Stiffness
Reproducibility of Results
Anatomy
medicine.anatomical_structure
Reference values
Elasticity Imaging Techniques
030211 gastroenterology & hepatology
Female
Elastography
Stress, Mechanical
medicine.symptom
business
Nuclear medicine
Subjects
Details
- ISSN :
- 20668643
- Volume :
- 18
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Medical ultrasonography
- Accession number :