S-MRUT: Sectored-Multiring Ultrasonic Transducer for Selective Powering of Brain Implants
- Source :
- Hosseini, S, Laursen, K, Rashidi, A, Mondal, T, Corbett, B & Moradi, F 2021, ' S-MRUT : Sectored-Multi Ring Ultrasonic Transducer for Selective Powering of Brain Implants ', IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol. 68, no. 1, 9112273, pp. 191-200 . https://doi.org/10.1109/TUFFC.2020.3001084
- Publication Year :
- 2020
-
Abstract
- One of the main challenges of the current ultrasonic transducers for powering brain implants is the complexity of focusing ultrasonic waves in various axial and lateral directions. The available transducers usually use electrically controlled phased array for beamforming the ultrasonic waves, which increases the complexity of the system even further. In this article, we propose a straightforward solution for selective powering of brain implants to remove the complexity of conventional phased arrays. Our approach features a Sectored-Multiring Ultrasonic Transducer (S-MRUT) on a single piezoelectric sheet, specifically designed for powering implantable devices for optogenetics in freely moving animals. The proposed unidirectional S-MRUT is capable of focusing the ultrasonic waves on brain implants located at different depths and regions of the brain. The S-MRUT is designed based on Fresnel Zone Plate (FZP) theory, simulated in COMSOL, and fabricated with the microfabrication process. The acoustic profile of the seven different configurations of the S-MRUT was measured using a hydrophone with the total number of 7436 grid points. The measurements show the ability of the proposed S-MRUT to sweep the focus point of the acoustic waves in the axial direction in depths of 1 – 3 mm, which is suitable for powering implants in the striatum of the mouse. Furthermore, the proposed S-MRUT demonstrates a steering area with an average radius of 0.862 mm and 0.678 mm in experiments and simulations, respectively. The S-MRUT is designed with the size of ${3.8}\times {3.8}\times {0.5}$ mm3 and the weight of ${0.054}{gr}$ , showing that it is compact and light enough to be worn by a mouse. Finally, the S-MRUT was tested in our measurement setup, where it successfully transfers sufficient power to a 2.8-mm3 optogentic stimulator to turn on a micro-LED on the stimulator.
- Subjects :
- Beamforming
Acoustic transducer
Materials science
Acoustics and Ultrasonics
Phased array
Acoustics
Uni-directional transducer
Transducers
Ultrasonic transducers
Zone plate
01 natural sciences
law.invention
Mice
law
Brain implant
0103 physical sciences
Animals
Ultrasonics
Electrical and Electronic Engineering
010301 acoustics
Instrumentation
Electrodes
Neural implants
Hydrophone
Brain
Acoustic wave
Equipment Design
Prostheses and Implants
Optogenetics
Transducer
Ultrasonic sensor
Subjects
Details
- ISSN :
- 15258955
- Volume :
- 68
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- IEEE transactions on ultrasonics, ferroelectrics, and frequency control
- Accession number :
- edsair.doi.dedup.....4a2729c92dc82b619161fc5d5685e624