Back to Search
Start Over
Optic Nerve Sheath Diameter Measured by Point-of-Care Ultrasound and MRI
- Source :
- Journal of neuroimaging : official journal of the American Society of NeuroimagingReferences. 30(6)
- Publication Year :
- 2020
-
Abstract
- BACKGROUND AND PURPOSE Ultrasound (US) measurement of the optic nerve sheath diameter (ONSD) and optic nerve diameter (OND) is a method frequently used to screen for an increased intracranial pressure. The aim of this study was to assess the accuracy of US measurements of ONSD and OND, when compared to magnetic resonance imaging (MRI) measurements as the criterion standard. METHODS In this prospective, single-institution study, orbital US was performed for those patients requiring an emergent brain MRI. ONSD and OND of both eyes were measured in the axial and coronal planes in straight gaze by US. ONSD and OND from brain and orbital MRI were measured by two neuroradiologists. Correlation and agreement between readings were assessed using Pearson's correlations. RESULTS Eighty-two patients met inclusion criteria. The mean axial and coronal ONSD in the MRI examinations was 5.6 and 5.7 mm at 3-5.9 mm behind the globe, respectively. The mean ONSD from the US measurements was 6.22 and 5.52 mm in the axial and coronal planes, respectively. The mean OND in US examinations was 4.31 mm (axial) and 3.68 mm (coronal). Axial versus coronal measurements of ONSD had a modest correlation in US assessment with an r2 of .385 (P < .001) but there were no correlations between any of the US and MRI measurements. CONCLUSIONS In measuring ONSD and OND, US measurements showed a modest correlation between axial and coronal measurements, but no concordance was found between US and MRI in our setting.
- Subjects :
- Adult
Male
Optic nerve sheath
Point-of-Care Systems
Neuroimaging
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Prospective Studies
Intracranial pressure
Aged
Ultrasonography
medicine.diagnostic_test
business.industry
Point of care ultrasound
Ultrasound
Magnetic resonance imaging
Optic Nerve
Middle Aged
Magnetic Resonance Imaging
Coronal plane
Optic nerve
Female
Neurology (clinical)
CRITERION STANDARD
Intracranial Hypertension
business
Nuclear medicine
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 15526569
- Volume :
- 30
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Journal of neuroimaging : official journal of the American Society of NeuroimagingReferences