Back to Search
Start Over
Design of a bioelectronic tongue for glucose monitoring using zinc oxide nanofibers and graphene derivatives
- Source :
- Scopus, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP, Sensors and Actuators Reports, Vol 3, Iss, Pp 100050-(2021)
- Publication Year :
- 2021
-
Abstract
- Made available in DSpace on 2022-04-28T19:49:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-11-01 Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) Monitoring glucose levels is critical for diabetes management and might be a key step in the development of individualized treatment strategies. In this scenario, tracking salivary glucose has been recognized as a promising strategy due to its merits of ease sampling and non-invasive nature. In this paper, we report on the development of an electrical impedance-based biosensor array to distinguish glucose at different concentrations in saliva. The enzymatic biosensors were made of gold interdigitated electrodes coated with pristine electrospun zinc oxide nanofibers (NFZ) and NFZ combined with graphene-based nanomaterials (i.e., reduced graphene oxide - rGO and graphene quantum dots - GQDs), on which a layer of glucose oxidase (GOx) enzyme was adsorbed. Electrical impedance measurements indicate that the NFZ-GQDs@GOx and NFZ-rGO@GOx platforms presented good linear relationship with glucose concentration in the range of 0.1 to 6 mM. The highest sensitivity was reached for NFZ-rGO@GOx with a detection limit (LOD) of 14 μM, while the LOD was 32 μM for NFZ-GQDs@GOx. Both biosensors were also capable of detecting glucose in artificial saliva using aliquots of 10 μL, with recovery between 87.3 and 106.8%. Furthermore, the three sensing units (NFZ@GOx, NFZ-rGO@GOx and NFZ-GQDs@GOx) were employed to build a bioelectronic tongue. Using Principal Component Analysis (PCA) technique to project the electrical impedance data of all sensing units allowed the discrimination of the different glucose concentrations and interferents. This study reveals the applicability of the developed bioelectronic tongue as non-invasive glucose sensors, which approach could also be pottentially adapted to detect other disease biomarkers present in saliva. Institute of Chemistry Federal University of Bahia (UFBA), BA Nanotechnology National Laboratory for Agriculture (LNNA) Embrapa Instrumentação, SP PPGQ Department of Chemistry Center for Exact Sciences and Technology Federal University of São Carlos (UFSCar), SP Physics Department Institute of Geosciences and Exact Sciences São Paulo State University (UNESP), SP Physics Department Institute of Geosciences and Exact Sciences São Paulo State University (UNESP), SP FAPESP: 2016/23793-4 FAPESP: 2017/10582-8 FAPESP: 2017/12174-4 FAPESP: 2018/22214-6
- Subjects :
- QA71-90
Glucose detection
Oxide
chemistry.chemical_element
Nanotechnology
Zinc
Instruments and machines
law.invention
Nanomaterials
chemistry.chemical_compound
law
Computer Science (miscellaneous)
Glucose oxidase
Reduced graphene oxide
Electrical and Electronic Engineering
Instrumentation
Biosensor array
Detection limit
Electrospun nanofibers
biology
Electrospinning
Chemistry
Graphene
Graphene quantum dots
Atomic and Molecular Physics, and Optics
Electronic, Optical and Magnetic Materials
Nanofiber
biology.protein
Biosensor
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Scopus, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP, Sensors and Actuators Reports, Vol 3, Iss, Pp 100050-(2021)
- Accession number :
- edsair.doi.dedup.....489360a5989217e06472c146b6bf4679