Back to Search
Start Over
Factors Affecting Outcomes in Cochlear Implant Recipients Implanted With a Perimodiolar Electrode Array Located in Scala Tympani
- Source :
- Otology & Neurotology. 37:1662-1668
- Publication Year :
- 2016
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2016.
-
Abstract
- To identify primary biographic and audiologic factors contributing to cochlear implant (CI) performance variability in quiet and noise by controlling electrode array type and electrode position within the cochlea.Although CI outcomes have improved over time, considerable outcome variability still exists. Biographic, audiologic, and device-related factors have been shown to influence performance. Examining CI recipients with consistent array type and electrode position may allow focused investigation into outcome variability resulting from biographic and audiologic factors.Thirty-nine adults (40 ears) implanted for at least 6 months with a perimodiolar electrode array known (via computed tomography [CT] imaging) to be in scala tympani participated. Test materials, administered CI only, included monosyllabic words, sentences in quiet and noise, and spectral ripple discrimination.In quiet, scores were high with mean word and sentence scores of 76 and 87%, respectively; however, sentence scores decreased by an average of 35 percentage points when noise was added. A principal components (PC) analysis of biographic and audiologic factors found three distinct factors, PC1 Age, PC2 Duration, and PC3 Pre-op Hearing. PC1 Age was the only factor that correlated, albeit modestly, with speech recognition in quiet and noise. Spectral ripple discrimination strongly correlated with speech measures.For these recipients with consistent electrode position, PC1 Age was related to speech recognition performance. Consistent electrode position may have contributed to high speech understanding in quiet. Inter-subject variability in noise may have been influenced by auditory/cognitive processing, known to decline with age, and mechanisms that underlie spectral resolution ability.
- Subjects :
- Adult
Male
medicine.medical_specialty
Perimodiolar electrode
medicine.medical_treatment
Audiology
Article
03 medical and health sciences
0302 clinical medicine
Cochlear implant
otorhinolaryngologic diseases
medicine
Electrode array
Humans
030223 otorhinolaryngology
Principal Component Analysis
business.industry
Scala Tympani
Cochlear Implantation
Sensory Systems
Cochlear Implants
Otorhinolaryngology
Speech Perception
Female
sense organs
Neurology (clinical)
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 15317129
- Volume :
- 37
- Database :
- OpenAIRE
- Journal :
- Otology & Neurotology
- Accession number :
- edsair.doi.dedup.....4717d51241bd04f56169ff16c7c55319
- Full Text :
- https://doi.org/10.1097/mao.0000000000001241