Back to Search
Start Over
Novel light-guide-PMT geometries to reduce dead edges of a scintillation camera
- Source :
- Physica Medica: an international journal devoted to the applications of physics to medicine and biology, 48
- Publication Year :
- 2018
-
Abstract
- Anger cameras based on monolithic NaI scintillators read out by an array of PMTs are predominant in planar gamma imaging and SPECT. However, position estimation of gamma interactions is usually severely degraded near the edges of the scintillator which can be extremely undesirable for applications like breast imaging. Here we propose a relatively cost-effective solution based on the use of scintillators with absorptive edges with an unconventional light-guide-PMT layout employing a maximum likelihood positioning algorithm. The basic design on which we aim to improve consists of a monolithic NaI(Tl) scintillator read out by 3 × 5 square PMTs (conventional layout, CL) that could be suitable for molecular breast imaging. To better detect gamma interactions near the crystal’s critical edge, we tried different set-ups: we replaced the 5 large PMTs near the edge by 11 smaller PMTs (small-sensor layout, SSL); we emulated rectangular PMTs along the critical edge by inserting a row of 5 rectangular light-guides that direct the light toward square PMTs placed behind (shifted layout, SL); we inserted rectangular light-guides alternatingly, such that the PMTs are in an interlocking pattern (alternating shifted layout, ASL). The performance of our designs was tested with Monte Carlo simulations. Results showed that SSL, SL, and ASL gave better spatial resolution near the critical edge than CL (3.4, 3.6, and 4.1 mm near the edge compared with 5.3 mm for CL), and thus resulted in a larger usable detector area. To conclude, for applications where small dead edges are crucial, our designs may be cost-effective solutions.
- Subjects :
- Photomultiplier
Light
Gamma-ray detectors
Monte Carlo method
Biophysics
General Physics and Astronomy
Edge (geometry)
Scintillator
01 natural sciences
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Optics
Planar
Photomultiplier tube
0103 physical sciences
Gamma Cameras
Radiology, Nuclear Medicine and imaging
Image resolution
Physics
Scintillation
010308 nuclear & particles physics
business.industry
Detector
General Medicine
Maximum likelihood estimation
Scintillation Counting
Dead edge
business
Subjects
Details
- Language :
- English
- ISSN :
- 11201797
- Database :
- OpenAIRE
- Journal :
- Physica Medica: an international journal devoted to the applications of physics to medicine and biology, 48
- Accession number :
- edsair.doi.dedup.....462755460f95d741bdb317e28e8a89be