Back to Search Start Over

Calorimetry of Heavy Charged Particle by Superconducting Transition-Edge Sensor

Authors :
Tomoya Irimatsugawa
Masashi Ohno
Chiko Otani
Yoshitaka Miura
Naruhiro Matsufuji
Makoto Sakama
Hiroyuki Takahashi
Tokihiro Ikeda
Source :
Journal of Low Temperature Physics. 193:1222-1227
Publication Year :
2018
Publisher :
Springer Science and Business Media LLC, 2018.

Abstract

Heavy ion cancer therapy allows the tumors to destroy while sparing surrounding, healthy tissues. By controlling the incident energy of heavy ions, the penetration depth can be adjusted precisely to the tumor area. The ionizing chambers are usually used for the determination of absorbed dose in the heavy ion irradiation fields; however, uncertainty in measurement of these detectors is expected to remain by more than 5%, and this has a negative influence on the therapeutic effect. Now we began to develop the precision heavy ion beam detector applying the superconducting transition-edge sensor (TES). Using the Ir/Au-TES coupled to a tin absorber, we have succeeded to detect the helium ions which were injected from Heavy Ion Medical Accelerator in Chiba. Although pulses are fully saturated because the temperature change is beyond the transition region, the signal length reflects the incident energy of each injected heavy ion. These results indicate the possibility of the precision heavy ion energy detection applying the TES detector.

Details

ISSN :
15737357 and 00222291
Volume :
193
Database :
OpenAIRE
Journal :
Journal of Low Temperature Physics
Accession number :
edsair.doi.dedup.....458da47a12495eff93dc96136ce8cfa4
Full Text :
https://doi.org/10.1007/s10909-018-2027-8