Back to Search
Start Over
Long-term Evaluation of Meniscal Tissue Formation in 3-dimensional-Printed Scaffolds With Sequential Release of Connective Tissue Growth Factor and TGF-β3 in an Ovine Model
- Source :
- Am J Sports Med
- Publication Year :
- 2019
-
Abstract
- Background:Artificial meniscal scaffolds are being developed to prevent development of osteoarthritis after meniscectomy. Previously, it was reported that 3-dimensional (3D) anatomic scaffolds loaded with connective tissue growth factor (CTGF) and transforming growth factor β3 (TGF-β3) achieved meniscal regeneration in an ovine model. This was a relatively short-term study (3 months postoperative), and outcome analyses did not include magnetic resonance imaging (MRI).Purpose:To evaluate long-term outcome of meniscal replacement with growth factor–laden poly-ε-caprolactone (PCL) scaffolds.Study Design:Controlled laboratory study.Methods:Anatomically shaped ovine meniscal scaffolds were fabricated from PCL with a 3D printer based on MRI data. Skeletally mature sheep (N = 34) were randomly allocated to 3 groups: scaffold without growth factor (0-µg group), scaffold with CTGF microspheres (µS) (5 µg) + TGF-β3 µS (5 µg) (5-µg group), and scaffold with CTGF µS (10 µg) + TGF-β3 µS (10 µg) (10-µg group). Unilateral medial meniscal replacement was performed. Animals were euthanized at 6 or 12 months. Regenerated meniscus, articular cartilage status, and synovial reaction were evaluated quantitatively with gross inspection, histology, and MRI. Kruskal-Wallis and Dunn tests were used to compare the 3 groups.Results:Remnants of the PCL scaffold were evident in the 6-month specimens and were decreased but still present at 12 months in most animals. There were no significant differences among groups in gross inspection, histology, or MRI for either meniscal regeneration or articular cartilage protection. All experimental groups exhibited articular cartilage degeneration as compared with control (nonoperated). In terms of synovitis, there were no clear differences among groups, suggesting that growth factors did not increase inflammation and fibrosis. MRI revealed that meniscal extrusion was observed in most animals (82.7%).Conclusion:Previously, the combination of CTGF and TGF-β3 was shown to stimulate mesenchymal stem cells into a fibrochondrocyte lineage. CTGF and TGF-β3 did not aggravate synovitis, suggesting no adverse response to the combination of 3D-printed PCL scaffold combined with CTGF and TGF-β3. Further work will be required to improve scaffold fixation to avoid meniscal extrusion.Clinical Relevance:A significant advantage of this technique is the ability to print custom-fit scaffolds from MRI-generated templates. In addition, average-size menisci could be printed and available for off-the-shelf applications. Based on the 1-year duration of the study, the approach appears to be promising for meniscal regeneration in humans.
- Subjects :
- Pathology
medicine.medical_specialty
medicine.medical_treatment
Connective tissue
Physical Therapy, Sports Therapy and Rehabilitation
Osteoarthritis
Meniscus (anatomy)
Article
03 medical and health sciences
0302 clinical medicine
Transforming Growth Factor beta3
medicine
Animals
Orthopedics and Sports Medicine
Meniscus
030304 developmental biology
030222 orthopedics
0303 health sciences
Sheep
Meniscal tissue
Tissue Scaffolds
business.industry
Growth factor
Connective Tissue Growth Factor
medicine.disease
medicine.anatomical_structure
Models, Animal
Printing, Three-Dimensional
business
Subjects
Details
- ISSN :
- 15523365
- Volume :
- 47
- Issue :
- 11
- Database :
- OpenAIRE
- Journal :
- The American journal of sports medicine
- Accession number :
- edsair.doi.dedup.....456bf1cf6ea59ea84dfa415f5b3107ad