Back to Search
Start Over
Measurement Of $^{144}\Rm{Ce}$ - $^{144}\Rm{Pr}$ Beta-Spectra With Si(Li) Detectors For The Purpose Of Determining The Spectra Of Electron Antineutrinos
- Publication Year :
- 2018
- Publisher :
- Zenodo, 2018.
-
Abstract
- S.V. Bakhlanov, A.V. Derbin, I.S. Drachnev, V.N. Muratova, N.V. Pilipenko, D.A. Semenov, E.V. Unzhakov St. Petersburg Nuclear Physics Institute National Research Center “Kurchatov Institute”, Gatchina, Russia The specifications of a newly developed beta-spectrometer, based on full absorption Si(Li) detector and thin transmission detector, are shown. The spectrometer allows to separate effectively beta-radiation and accompanying X-rays and gamma radiation using registration of coincident events from both detectors. The spectrometer can be used for precision measurements of various beta-spectra, namely for the beta-spectrum shape study of 144Pr ^{144}\rm{Pr} , which is considered to be an advantageous anti-neutrino source for sterile neutrino searches. The preliminary results for beta spectra from 144Ce−144Pr ^{144}\rm{Ce}-^{144}\rm{Pr} decays and reconstructed antineutrino spectra are presented.
Details
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....4368b2dfc1168211313e0ec8398ead05
- Full Text :
- https://doi.org/10.5281/zenodo.1300454