- Objective To obtain reference values for the isometric endurance test (IET) of the cervical flexor muscles, investigate its reproducibility, and compare the results with the maximal isometric strength test (MIST) of the cervical flexor muscles. Design Cross-sectional non-comparative study with single group repeated measurements. Methods Altogether 219 healthy females aged 20–59 years volunteered to participate in the study. The IET was performed in the supine position and MIST seated. The reproducibility was evaluated by the intraclass correlation coefficient (ICC) and an analysis described by Bland and Altman. The relationship between the two measuring methods was evaluated by Pearson's correlation coefficient. Results The mean (SD) IET time was 60 (33) seconds with no significant differences between the age groups of each decade. The ICC for intrarater repeatability was 0.80. However, the Bland-Altman analysis suggested moderate variation in repeated measurements. Pearson's correlation coefficient between the IET and MIST was 0.56. Conclusion Normative reference values for the IET are presented. Although the ICC showed good repeatability, one should consider that the change at follow-up visits has to be considerable to be clinically relevant. The correlation between the endurance time and maximal flexion strength was moderate. Thus IET of the cervical flexor muscles may be used in the clinic like the Biering-Sorenson test has been used to assess fatigue of the trunk extensor muscles.
- Subjects :
- Complementary and Manual Therapy
Adult
medicine.medical_specialty
Supine position
Correlation coefficient
Intraclass correlation
endurance strength
Physical Therapy, Sports Therapy and Rehabilitation
Isometric exercise
non-specific neck pain
isometric contraction
03 medical and health sciences
Disability Evaluation
Young Adult
0302 clinical medicine
intrarater reliability
Neck Muscles
Reference Values
Isometric Contraction
medicine
Humans
Muscle, Skeletal
030222 orthopedics
Reproducibility
business.industry
Rehabilitation
niska
kipu
Reproducibility of Results
ta3141
Intra-rater reliability
Repeatability
Middle Aged
Trunk
Cross-Sectional Studies
Complementary and alternative medicine
maximal strength
Physical therapy
Female
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 15329283
- Volume :
- 21
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Journal of bodywork and movement therapies
- Accession number :
- edsair.doi.dedup.....42190520d73044feeb055c0a26f8b177