Back to Search Start Over

Applicability of TASS/SMR using drift flux model for SMART LOCA analysis

Authors :
Soo Hyung Kim
Won-Jae Lee
Young-Jong Chung
Gyu Hyeung Lee
Source :
Nuclear Engineering and Design. 262:228-234
Publication Year :
2013
Publisher :
Elsevier BV, 2013.

Abstract

Small reactors can apply to local power demands or remote areas. SMART, which can produce 90 MWe of electricity and 40,000 tons/day of sea-water desalination for a 100,000 population city, is a promising advanced integral type small reactor. The thermal hydraulic analysis code with a drift flux model, TASS/SMR, was developed for a conservative simulation of a small break loss of coolant accident in SMART. Taking into account SMART-specific inherent characteristics, the code adopts the Chexal–Lellouche correlation for a drift flux model. The capability of TASS/SMR code is validated using the results of the experimental data. The code predicts conservatively the void distribution compared with the experimental data. TASS/SMR calculation predicts reasonably major phenomena for the SBLOCA and is more conservative than or nearly the same as the results of the best estimated realistic system code, MARS. TASS/SMR code can be used for a SBLOCA analysis of SMART.

Details

ISSN :
00295493
Volume :
262
Database :
OpenAIRE
Journal :
Nuclear Engineering and Design
Accession number :
edsair.doi.dedup.....420d1f1100ea25a002cefabb2dcf4318
Full Text :
https://doi.org/10.1016/j.nucengdes.2013.04.020