Back to Search
Start Over
High-resolution multi-parameter DNA flow cytometry enables detection of tumour and stromal cell subpopulations in paraffin-embedded tissues
- Source :
- The Journal of Pathology. 206:233-241
- Publication Year :
- 2005
- Publisher :
- Wiley, 2005.
-
Abstract
- The accuracy of DNA ploidy measurements of paraffin-embedded tissues is limited by the lack of resolution and the inability to identify the DNA diploid population unequivocally in bimodal DNA histograms. A multi-parameter DNA flow cytometric method has been developed that enables the simultaneous detection of neoplastic and stromal cells in samples from dewaxed 50 µm sections or 2 mm diameter punches of archival tissue blocks. The method combines heat pretreatment in sodium citrate buffer and subsequent enzymatic dissociation with a collagenase/dispase mixture. Cells were simultaneously stained for keratin (FITC), vimentin (R-PE), and DNA (PI) before flow cytometric analysis. The method was applied to 12 paraffin-embedded cervical carcinomas and four colorectal carcinomas. In all cervical cancers, distinct keratin-positive and vimentin-positive cell populations were observed. While the exclusive vimentin-positive cell fractions always yielded unimodal DNA content distributions, bimodal distributions were observed for the keratin-positive cell fractions in nine cervical carcinomas, whereas one cervical carcinoma showed three distinct G0G1 populations. Coefficients of variation of the G0G1 peaks ranged from 1.70% to 4.79%. Average background, aggregate, and debris values were 14.7% (vimentin-positive fraction) and 33.8% (keratin-positive fraction). Flow sorting confirmed that the exclusively vimentin-positive cell fractions represent different normal stromal and infiltrate cells that can serve as an internal ploidy reference enabling discrimination between DNA hypo-diploid and DNA hyper-diploid tumour cell subpopulations. The neoplastic origin of the keratin–vimentin co-expressing cells from two cervical carcinomas was confirmed by genotyping of flow-sorted samples revealing loss of heterozygosity (LOH) of 6p. This improved method obviates the need for fresh/frozen tumour tissue for high-resolution DNA ploidy measurements and enables the isolation of highly purified tumour subpopulations for subsequent genotyping. Copyright © 2005 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.
- Subjects :
- Pathology
medicine.medical_specialty
Hot Temperature
Tissue Fixation
Stromal cell
Tumour heterogeneity
Population
Cell
Loss of Heterozygosity
Uterine Cervical Neoplasms
Biology
Pathology and Forensic Medicine
Flow cytometry
chemistry.chemical_compound
Formaldehyde
Keratin
medicine
Humans
Vimentin
education
Genotyping
chemistry.chemical_classification
education.field_of_study
Paraffin Embedding
Ploidies
medicine.diagnostic_test
Antibodies, Monoclonal
DNA, Neoplasm
Flow Cytometry
Neoplasm Proteins
medicine.anatomical_structure
chemistry
Keratins
Female
Stromal Cells
Colorectal Neoplasms
DNA
Subjects
Details
- ISSN :
- 10969896 and 00223417
- Volume :
- 206
- Database :
- OpenAIRE
- Journal :
- The Journal of Pathology
- Accession number :
- edsair.doi.dedup.....41fb148974f98a60791e8b02c347850e
- Full Text :
- https://doi.org/10.1002/path.1765