Back to Search
Start Over
Use of potassium-form cation-exchange resin as a conductimetric enhancer in ion-exclusion chromatography of aliphatic carboxylic acids
- Source :
- Talanta. 79(4):1026-1030
- Publication Year :
- 2009
- Publisher :
- Elsevier Science BV, 2009.
-
Abstract
- In this study, a cation-exchange resin (CEX) of the K(+)-form, i.e., an enhancer resin, is used as a postcolumn conductimetric enhancer in the ion-exclusion chromatography of aliphatic carboxylic acids. The enhancer resin is filled in the switching valve of an ion chromatograph; this valve is usually used as a suppressor valve in ion-exchange chromatography. An aliphatic carboxylic acid (e.g., CH(3)COOH) separated by a weakly acidic CEX column of the H(+)-form converts into that of the K(+)-form (e.g., CH(3)COOK) by passing through the enhancer resin. In contrast, the background conductivity decreases because a strong acid (e.g., HNO(3)) with a higher conductimetric response in an eluent converts into a salt (e.g., KNO(3)) with a lower conductimetric response. Since the pH of the eluent containing the resin enhancer increases from 3.27 to 5.85, the enhancer accelerates the dissociations of analyte acids. Consequently, peak heights and peak areas of aliphatic carboxylic acids (e.g., acetic acid, propionic acid, butyric acid, and valeric acid) with the enhancer resin are 6.3-8.0 times higher and 7.2-9.2 times larger, respectively, than those without the enhancer resin. Calibrations of peak areas for injected analytes are linear in the concentration range of 0.01-1.0mM. The detection limits (signal-to-noise ratio=3) range from 0.10 microM to 0.39 microM in this system, as opposed to those in the range of 0.24-7.1 microM in the separation column alone. The developed system is successfully applied to the determination of aliphatic carboxylic acids in a chicken droppings sample.
- Subjects :
- Valeric acid
Conductometry
Carboxylic acid
Ion chromatography
Carboxylic Acids
Cation exchange
Analytical Chemistry
Butyric acid
chemistry.chemical_compound
Acetic acid
Feces
Column chromatography
Animals
Ion-exchange resin
chemistry.chemical_classification
Chromatography
Chromatography, Ion Exchange
chemistry
Ion-exclusion chromatography
Conductimetric enhancer
Calibration
Linear Models
Potassium
Ion Exchange Resins
Aliphatic carboxylic acids
Chickens
Subjects
Details
- Language :
- English
- Volume :
- 79
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Talanta
- Accession number :
- edsair.doi.dedup.....41e3453eff2428492d46629ea0b71e63