Back to Search Start Over

Prediction of degree of carotid stenosis with the transluminal attenuation difference ratio

Authors :
Ömer Suat Fitoz
Ayşegül Gürsoy Çoruh
Atilla Halil Elhan
Elif Peker
Başak Gülpınar
Mine Hayriye Sorgun
Source :
Diagn Interv Radiol
Publication Year :
2020
Publisher :
Galenos Yayinevi, 2020.

Abstract

PURPOSE: We aimed to assess the diagnostic performance of transluminal attenuation difference (TAD) in predicting the severity of internal carotid artery (ICA) stenosis. METHODS: The study cohort consisted of 48 patients with 70%) stenosis compared with control arteries and low-moderate stenosis. A TAD ratio cutoff of 4.5 predicted 70%–99% stenosis with a sensitivity of 100% and specificity of 93%. The inter- and intraobserver agreements in TAD measurements were almost perfect (ICC, 0.89–0.86). CONCLUSION: Assessment of TAD ratio predicts the degree of stenosis in concordance with NASCET system.

Details

ISSN :
13053612
Volume :
26
Database :
OpenAIRE
Journal :
Diagnostic and Interventional Radiology
Accession number :
edsair.doi.dedup.....418dcdd7ff2d1c73baef1e5d073d7d6d
Full Text :
https://doi.org/10.5152/dir.2019.19259