Back to Search
Start Over
Measurement of cutaneous erythema by means of photodensitometry: application to cutaneous photosensitivity
- Source :
- Photodermatology, photoimmunologyphotomedicine. 14(3-4)
- Publication Year :
- 1998
-
Abstract
- We have developed a photodensitometry method to evaluate the intensity of cutaneous erythema objectively. The method measures the optical density of photographic slides of cutaneous erythema. It combines techniques used commonly but separately by investigators: diffuse transmittance spectroscopy (which is a variant of diffuse reflectance spectroscopy) and photography. We have used this method to study photosensitivity in 22 volunteers who received increasing doses of ultraviolet radiation to the back. Our work confirms the usefulness of an important parameter in photobiology: the regression slope of the curve representing the erythema index, a function of the logarithm of the dose applied.
- Subjects :
- Adult
Male
medicine.medical_specialty
genetic structures
Diffuse reflectance infrared fourier transform
Erythema
Ultraviolet Rays
Immunology
Dermatology
Optical density
Photosensitivity
medicine
Photography
Immunology and Allergy
Humans
Radiology, Nuclear Medicine and imaging
Cutaneous photosensitivity
Ultraviolet radiation
Skin
Chemistry
General Medicine
Middle Aged
Photographic slides
Female
medicine.symptom
Diffuse transmittance
Densitometry
Subjects
Details
- ISSN :
- 09054383
- Volume :
- 14
- Issue :
- 3-4
- Database :
- OpenAIRE
- Journal :
- Photodermatology, photoimmunologyphotomedicine
- Accession number :
- edsair.doi.dedup.....4186a9c4b1b117ecafb5686f3032a3c7