Back to Search Start Over

Comparable Pharmacokinetics, Safety, and Tolerability of Etrolizumab Administered by Prefilled Syringe or Autoinjector in a Randomized Trial in Healthy Volunteers

Authors :
Helen Tyrrell
Jennifer Pulley
Wenhui Zhang
Renato Ravanello
Han Ting Ding
Rich Erickson
Meina Tao Tang
Audrey Boruvka
Mariam Abouhossein
Source :
Advances in Therapy
Publication Year :
2021
Publisher :
Springer Healthcare, 2021.

Abstract

Introduction Etrolizumab is a novel, dual-action anti-β7 integrin antibody studied in phase 3 trials in patients with inflammatory bowel disease. An autoinjector (AI) is being developed in parallel to complement the prefilled syringe with needle safety device (PFS-NSD) for subcutaneous (SC) administration in these trials. Here we demonstrate the comparable pharmacokinetics, tolerability, and safety of both devices. Methods This randomized, open-label, two-part study in healthy participants evaluated the comparability of etrolizumab exposure between the AI and the PFS-NSD. Part 1 (pilot) involved a small number of participants, and initial results were used to finalize the design of the larger part 2 (pivotal) study. In both parts, participants were randomly assigned to receive a single SC dose of etrolizumab 105 mg by AI or PFS-NSD. Randomization was stratified by body weight. Primary pharmacokinetic outcomes were Cmax, AUClast, and AUC0–inf. Results One hundred and eighty healthy participants (part 1, n = 30; part 2, n = 150) received a single SC dose of etrolizumab by AI or PFS-NSD. Primary pharmacokinetic results from part 1 supported modification of the part 2 study design. Results from part 2 demonstrated that etrolizumab exposure was equivalent between devices, with geometric mean ratios (GMRs) between AI and PFS-NSD of 102% (90% confidence interval [CI] 94.2–111) for Cmax, 98.0% (90% CI 89.3–107) for AUClast, and 97.6% (90% CI 88.6–107) for AUC0–inf. Median tmax and mean terminal t1/2 were also similar between devices. GMRs and 90% CIs of all primary pharmacokinetic parameters were fully contained within the predefined equivalence limits (80–125%). Conclusion This pharmacokinetic study demonstrated that single SC injections of etrolizumab 105 mg using an AI or a PFS-NSD resulted in equivalent etrolizumab exposure and similar safety and tolerability in healthy participants. Taken together, these results support the use of an AI for etrolizumab administration. Trial Registration NCT02996019.

Details

Language :
English
ISSN :
18658652 and 0741238X
Volume :
38
Issue :
5
Database :
OpenAIRE
Journal :
Advances in Therapy
Accession number :
edsair.doi.dedup.....407ccd54651f54ed9ac1c70c9f00e2b9