No difference in early cellular response of the pseudo-synovial membrane after total hip arthroplasty: Comparison of 3 combinations of bearing materials
- Source :
- Acta Orthopaedica. 77:402-412
- Publication Year :
- 2006
- Publisher :
- Medical Journals Sweden AB, 2006.
-
Abstract
- Wear-resistant bearing materials may hypothetically reduce chronic inflammation in the pseudosynovial membrane as compared to less wear-resistant bearing materials such as polyethylene. We assessed the foreign body response in the pseudosynovial membrane in vivo after total hip replacement.37 patients from a larger prospective randomized trial of 225 patients had biopsies taken arthroscopically from the artificial hip joint (i.e. the pseudosynovial membrane) 1 year after insertion of the implant. All patients had an identical hip prosthesis (Bimetric-RingLoc) except for the bearing materials, which consisted of polyethylene on zirconia, CoCr on CoCr, or alumina on alumina. Histological quantification was performed on 2-mum-thick semi-thin plastic sections or paraffin sections by point counting technique to compare the volume fraction of macrophages, granulomas and endothelial cells in biopsies of the pseudosynovial membrane.The median macrophage volume fractions for polyethylene-on-zirconia bearing material (n = 15), CoCr-on-CoCr (n = 9), and alumina-on-alumina (n = 11) were 0.02, 0.04, and 0.004, respectively. The median granuloma volume fractions for polyethylene-on-zirconia (n = 13), CoCr-on-CoCr (n = 9), and alumina-on-alumina (n = 13) were 0.02, 0.04, and 0.02, respectively. The median endothelial cell volume fractions for polyethylene-on-zirconia (n = 15), CoCr-on-CoCr (n = 9), and alumina-on-alumina (n = 11) were 0.03, 0.02, and 0.05, respectively. Statistical analysis showed no significant differences between the three groups with the different bearings with respect to volume fraction of macrophages, granulomas and endothelial cells.Our study demonstrated that a granulomatous inflammation is a common finding in non-loose implants as early as 1 year after the operation not demonstrating a difference in macrophages and granuloma formation with the various bearing materials. Thus a high volume fraction of macrophages was found in the osteoarthritis control group compared to the operated group.
- Subjects :
- Adult
Male
Pathology
medicine.medical_specialty
Chirurgie orthopedique
Arthroplasty, Replacement, Hip
Biopsy
Prosthesis Design
Osteoarthritis, Hip
law.invention
Femur Head Necrosis
law
Materials Testing
Arthropathy
medicine
Humans
Orthopedics and Sports Medicine
Prospective Studies
Aged
Aged, 80 and over
Bearing (mechanical)
business.industry
Foreign-Body Reaction
Granuloma, Foreign-Body
Synovial Membrane
General Medicine
Middle Aged
medicine.disease
Prosthesis Failure
Membrane
medicine.anatomical_structure
Female
Surgery
Hip Prosthesis
Implant
Synovial membrane
business
human activities
Follow-Up Studies
Biomedical engineering
Total hip arthroplasty
Subjects
Details
- ISSN :
- 17453682 and 17453674
- Volume :
- 77
- Database :
- OpenAIRE
- Journal :
- Acta Orthopaedica
- Accession number :
- edsair.doi.dedup.....406029e2e029bfeb24daed1f51d80bec
- Full Text :
- https://doi.org/10.1080/17453670610046325